Top mount refrigerators – FRIGIDAIRE FFTR1814QS User Manual
Page 3
Specifications
subject to change.
USA
•
10200 David Taylor Drive
•
Charlotte, NC 28262
•
1-800-FRIGIDAIRE
•
frigidaire.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
frigidaire.ca
Top Mount Refrigerators
FFTR1814Q 10/14
© 2014 Electrolux Home Products, Inc.
FFTR1814Q S / W / B
18 Cu. Ft.
Top Mount Refrigerator Specifications
•
Product Shipping Weight (approx.) – 205 Lbs.
•
An electrical supply with grounded three-prong receptacle is
required. The power supply circuit must be installed in accordance
with current edition of National Electrical Code (NFPA 70) and
local codes & ordinances.
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = .72 kW
•
Amps @ 120 Volts = 6.0 Amps
•
Always consult local and national electric & plumbing codes.
•
Floor should be level surface of hard material, capable of supporting
fully loaded refrigerator.
•
Minimum 3/8" clearance required for sides and top of refrigerator
with 1" clearance at rear to allow for ease of installation, proper air
circulation, and plumbing / electrical connections.
•
When installing refrigerator adjacent to wall, cabinet or other
appliance that extends beyond front edge of unit, 20" minimum
clearance recommended to allow for optimum 140° door swing,
providing complete crisper access and removal. (Absolute 3"
minimum clearance will ONLY allow for 90° door swing which
will provide limited crisper access with restricted removal.)
•
To ensure optimum performance, do not install in areas where
temperature drops below 55° F or rises above 110° F and
avoid installing in direct sunlight or close proximity to range,
dishwasher or other heat source.
•
For proper ventilation, front grille MUST remain unobstructed.
•
Recess electrical outlet when possible.
•
Optional Ice Maker Kit (PN # IM116) available for installation in
ice maker-ready models only.
•
Water recess on rear wall recommended to prevent water line damage.
•
Water Pressure – Cold water line must provide between 30 and 100
pounds per square inch (psi).
•
Copper tubing with 1/4" O.D. recommended for water supply line
with length equal to distance from rear of unit to household water
supply line plus 7 additional feet. Optional Water Supply Installation
Kits available.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
•
Ice Maker Kit – (PN # IM116).
Top Mount Refrigerator - 18 Cu. Ft.
Baseline Q 2014
Top View
Allow 1" min. clearance at rear
for proper air circulation and
water / electrical connections
Allow
3
/
8
" min. clearance at sides
and top for ease of installation
Recessed water line
(ice maker models only)
Recessed
electrical outlet
* When installing refrigerator adjacent to wall,
cabinet or other appliance that extends beyond front
edge of unit, 20" minimum clearance recommended
to allow for optimum 140° door swing, providing
complete crisper access and removal. (Absolute
3" minimum clearance will ONLY allow for 90° door
swing which will provide limited crisper access
with restricted removal.)
When installing directly
adjacent to wall, sufficient
handle clearance required
where handle may make
contact with wall, to allow
for 90° door opening*
29
5
/
8
"
Power
cord
location
(right
bottom
rear)
Water
line inlet
location
(left
bottom
rear)
Allow 58
1
/
2
" min.
(with doors 90° open)
29
7
/
8
"
26
5
/
8
"
32
1
/
4
"
66
1
/
8
"
with
3
/
8
"
rollers
65
3
/
8
"
with
3
/
8
"
rollers