beautypg.com

30" combination installation – FRIGIDAIRE FGEW3065KW User Manual

Page 6

background image

Specifications

subject to change.

30" Electric Single Wall Oven Specifications

Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz

AC only electrical supply with ground required on separate circuit

fused on both sides of line.

For detailed electrical requirements, refer to model-specific product

page and installation guide on web.

To support Wall Oven when using in combination with Warmer

Drawer, two 3"-wide x 3/4"-thick planks must be installed as a base,

capable of supporting 200 Lbs. Do NOT use full base, since planks

are necessary to allow for proper air displacement.

30" Warmer Drawer Specifications

Voltage Rating – 120V / 450W / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 0.5 kW

(For use on adequately wired 120V, dedicated circuit having 2-wire

service with a separate ground wire. Appliance must be grounded

for safe operation.)

Amps @ 120V = 3.8 Amps

Full base of solid plywood or similar material required, capable of

supporting 100 Lbs.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

30" Combination Installation Specifications

Always consult local and national electric codes.

(Refer to product-specific electrical specifications on this page.)

Minimum 23-5/8" deep cutout dimension is critical for proper

combination installation, to ensure that each built-in product’s

faceplate will fit flush against cabinet front.

Bases must be level and cabinet front must be square.

Minimum 4-1/2" required distance from bottom of Warmer Drawer

cutout to floor.

Respect critical dimensions as noted for proper installation of

built-In products.

Minimum 21" clearance needed for Wall Oven door depth when open.

30" Built-In Microwave Specifications

For built-in installation, microwave MUST be installed with optional

30" Trim Kit which includes Bottom Duct Assembly – shipped in

separate box, ordered by individual part number.

Voltage Rating – 120V / 60 Hz / 15 or 20 Amps

Connected Load (kW Rating) @ 120 Volts = 1.7 kW

(For use on adequately wired 120V, dedicated circuit having 2-wire

service with a separate ground wire. Appliance must be grounded

for safe operation.)

Amps @ 120 Volts = 14.3 Amps

Full oven base of solid plywood or similar material required, capable

of supporting 100 Lbs.

Minimum 2-7/8" clearance required from bottom of Built-In Microwave

cutout to top edge of Wall Oven’s faceplate, leaving a 2" visible gap

between both product faceplates.

30" Combination Installation

Built-In Microwave / Single Wall Oven / Warmer Drawer

USA

10200 David Taylor Drive

Charlotte, NC 28262

1-800-FRIGIDAIRE

frigidaire.com

CANADA

5855 Terry Fox Way

Mississauga, ON L5V 3E4

1-800-265-8352

frigidaire.ca

MOSS24_EW_WD 30INST FR 02/12

© 2012 Electrolux Home Products, Inc.

Frigidaire 30" Combination Installation –

24" Built-In Microwave (with 30" Trim Kit)

Electric Single Wall Oven

Warmer Drawer

This manual is related to the following products: