1 Turn off power supply to outlet.
2 Remove the screw securing the terminal block

access cover on the back of the dryer.

3 Install a UL-approved strain relief according to the

power cord/strain relief manufacturer’s instructions

in the power cord entry hole below the access

panel. At this time, the strain relief should be

loosely in place.

4 Thread an UNPLUGGED, UL-approved, 30 amp.

power cord, NEMA 10-30 type SRDT, through the

strain relief.

5 Attach the power cord neutral (center wire)

conductor to the SILVER colored center terminal on

the terminal block. Tighten the screw securely.

6 Attach the remaining two power cord outer

conductors to the outer, BRASS colored terminals on

the terminal block. Tighten both screws securely.

7 Follow manufacturer’s guidelines for fi rmly securing

the strain relief and power cord.

8 Reinstall the terminal block cover.

Neutral

terminal

DO NOT remove

internal ground in a

3-wire system!

Electrical connection (non-Canada) - 3 wire cord

3-wire receptacle

(NEMA type 10-30R)

Neutral

Neutral

(center wire)

(center wire)

30 AMP

30 AMP

NEMA 10-30

NEMA 10-30

WARNING

ELECTRICAL SHOCK HAZARD

Failure to disconnect power source before servicing

could result in personal injury or even death.

WARNING

ELECTRICAL SHOCK HAZARD

Do not make a sharp bend or crimp wiring/conductor

at connections.

IMPORTANT

If moving dryer from a 4-wire system and installing it

in a 3-wire system, move the internal ground from the

center terminal back to the GREEN screw next to the

terminal block.