beautypg.com

Top mount refrigerators – FRIGIDAIRE FFTR2021QS User Manual

Page 3

background image

Specifications

subject to change.

USA

10200 David Taylor Drive

Charlotte, NC 28262

1-800-FRIGIDAIRE

frigidaire.com

CANADA

5855 Terry Fox Way

Mississauga, ON L5V 3E4

1-800-265-8352

frigidaire.ca

Top Mount Refrigerators

FFTR2021Q 08/14

© 2014 Electrolux Home Products, Inc.

FFTR2021Q S / W / B

20 Cu. Ft.

Top Mount Refrigerator Specifications

Product Shipping Weight (approx.) – 220 Lbs.

An electrical supply with grounded three-prong receptacle is

required. The power supply circuit must be installed in accordance

with current edition of National Electrical Code (NFPA 70) and

local codes & ordinances.

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 0.72 kW

Amps @ 120 Volts = 6.0 Amps

Always consult local and national electric & plumbing codes.

Floor should be level surface of hard material, capable of supporting

fully loaded refrigerator.

Minimum 3/8" clearance required for sides and top of refrigerator

with 1" clearance at rear to allow for ease of installation, proper air

circulation, and plumbing / electrical connections.

When installing refrigerator adjacent to wall, cabinet or other

appliance that extends beyond front edge of unit, 20" minimum

clearance recommended to allow for optimum 140° door swing,

providing complete crisper access and removal. (Absolute 3"

minimum clearance will ONLY allow for 90° door swing which

will provide limited crisper access with restricted removal.)

To ensure optimum performance, do not install in areas where

temperature drops below 55° F or rises above 110° F and

avoid installing in direct sunlight or close proximity to range,

dishwasher or other heat source.

For proper ventilation, front grille MUST remain unobstructed.

Recess electrical outlet when possible.

Optional Ice Maker Kit (PN # IM116) available for installation in

ice maker-ready models only.

Water recess on rear wall recommended to prevent water line damage.

Water Pressure – Cold water line must provide between 30 and 100

pounds per square inch (psi).

Copper tubing with 1/4" O.D. recommended for water supply line

with length equal to distance from rear of unit to household water

supply line plus 7 additional feet. Optional Water Supply Installation

Kits available.

Adjustable front rollers to assist with door alignment.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

Optional Accessories

Ice Maker Kit – (PN # IM116).

Top Mount Refrigerator - 20 Cu. Ft.

Baseline Q 2014

Top View

Allow 1" min. clearance at rear

for proper air circulation and

water / electrical connections
Allow

3

/

8

" min. clearance at sides

and top for ease of installation

Recessed water line

(ice maker models only)

Recessed

electrical outlet

* When installing refrigerator adjacent to wall,

cabinet or other appliance that extends beyond front

edge of unit, 20" minimum clearance recommended

to allow for optimum 140° door swing, providing

complete crisper access and removal. (Absolute

3" minimum clearance will ONLY allow for 90° door

swing which will provide limited crisper access

with restricted removal.)

When installing directly

adjacent to wall, sufficient

handle clearance required

where handle may make

contact with wall, to allow

for 90° door opening*

29

5

/

8

"

Power

cord

location

(right

bottom

rear)

Water

line inlet

location

(left

bottom

rear)

Allow 60" min.

(with doors 90° open)

31

3

/

4

"

28

1

/

2

"

34

1

/

8

"

69"

with

3

/

8

"

rollers

68

1

/

4

"

with

3

/

8

"

rollers

This manual is related to the following products: