Freezer ice maker information
SERVICE DATA SHEET
242292200
ICE & WATER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch
to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive
heat will distort the plastic liner.
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
CONTROL SETTING
Type A with Run / Start
Capacitor
65°F (18°C) Ambient
90°F (32°C) Ambient
Operating Time
90 to 100%
100%
Freezer Temperature
-5° to 2°F (-20° to -17°C)
-1° to 3°F (-18° to -16°C)
Refrigerator Temperature
34° to 39°F (1° to 4°C)
34° to 39°F (1° to 4°C)
Low Side Pressure
-2 to 6 psig ( -14 to 41 kPa)
-2 to 6 psig (-14 to 41 kPa)
High Side Pressure (last 1/3
cycle)
85 to 105 psig (586 to 724 kPa)
120 to 135 psig (827 to 931
kPa)
Wattage (last 1/3 cycle)
30 to 50
50 to 70
Amps (running)
.4 to .8
.7 to .9
Base Voltage
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size
Thermostat
Heater
Cut-in
Cut-out
Watts
Ohms
26’ & 28’ SD, 23’ CD
25°F (-4°C)
47°F
(8°C)
500
26.5
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run
time.
CONDENSER FAN MOTOR
Watts
RPM
Amps
3.1
1100 CW Opposite Shaft
0.03 Running
FREEZER ICE MAKER SPECIFICATIONS
Electrical
115 vac (127 vac max)
Thermostat
Opens at 48°F ( 9°C), Closes at 15° F ( -9°C)
Heater Voltage
115 vac
FREEZER ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number
Wire Color
Connects to:
1
Green / Yellow
Ground
2
Yellow
Water Valve
3
Black
Line
4
Light Blue
Neutral
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should
not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing
this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position
and properly secured.
System Diagnostic Mode
Activate:
Press ٨ and
٧ for up to 10 sec. simultaneously.
Deactivate:
Press
+ for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
Note: Silence alarm.
• Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.
Test
To activate test:
Passing result
--
First Screen
--
All LED lights on UI illuminated
--
Second Screen
--
All segments on UI temperature displays illuminated
--
Third Screen
--
Blank UI display, no lights illuminated, no shadowing; “-” and “+”
blinking on FF display side to show location.
28
Dispenser Paddle
Press disp. paddle
“on” on UI when depressed; “off” when released
1*
Standard
Compressor
Set
Compressor running when “on”; stopped when “off”
2
Defrost Heater
Set
Defrost limit switch must be closed; verify “CL” in test 26.
Feel for heat from defrost heater when “on”.
If “OP” in test 26, heater will not activate.
3
FF Light
Set
With FF door open, FF lights on when “on”; off when “off”
8
Water Valve
(Dispenser)
Set
FF door must be closed.
Be prepared to collect water at dispenser.
Water dispenses when “on”; stops when “off”
9
FZ Light
Set
With FZ door open, FZ lights on when “on”, off when “off”
10
Auger Motor
Set
FF door must be closed.
Motor running when “on”; motor stopped when “off”
11
Cube/Crush
Solenoid
Set
FF door must be closed.
Do not leave solenoid in activated state.
Solenoid activated when “on”; deactivated when “off”
41*
Perfect Temp
Drawer (PTD)
Set
PTD UI illuminated when “on”, off when “off”
12*
VCC Condenser
Fan
Set
Fan running when “on”; stopped when “off”
38*
VCC Compressor
Set
Compressor running when “on”; stopped when “off”
15
Evaporator Fan
Set
Fan running for
minimum of 10 sec. when “LO” or “HI”; stopped when
“off”. Feedback failure if fan starts but runs less than 10 sec. Listen for
speed change from “LO” to “HI”.
36
Ice Chute Door
Depress ice chute
door or set
“OP” on UI when manually opened; “CL” when closed. Or, using “power
on-off”, “OP” on UI when solenoid activated, “CL” when deactivated
22
Damper
Set
With inspection mirror, observe damper open when “OP”; closed when “CL”
23
FF Door
Open/close FF door
“CL” on UI when door closed; “OP” when open
24
FZ Door
Open/close FZ door
“CL” on UI when door closed; “OP” when open
26
Defrost Limit Switch Activates automati-
cally
“CL” on UI when closed; “OP” when open
29
FF Thermistor
Mid-level
Activates automati-
cally
UI shows temperature sensed by FF thermistor; pass if within 10°F of
temperature measured with gauge at mid-level FF thermistor location.
“OP-” if open; “SH-” if short
30
FZ Thermistor
Activates automati-
cally
UI shows temperature sensed by FZ thermistor; pass if within 10°F of tempera-
ture measured with gage at FZ thermistor location.
“OP” if open; “SH” if short
33
Ambient Thermistor
@ Main Board
Activates automati-
cally
UI shows temperature sensed at main board; pass if within +20°F/-
10°F of temperature measured with gauge at main board location.
“OP” if open; “SH” if short
35*
FF Thermistor
Upper-Level
Activates automati-
cally
UI shows temperature sensed by upper level FF thermistor; pass if
within 10°F of temperature measured with gauge at upper-level FF
thermistor location. “OP¯” if open; “SH¯” if short
34*
Ambient Thermistor
@ UI
Activates automati-
cally
UI shows temperature sensed at UI; pass if within +20°F/-10°F of tem-
perature measured with gauge at UI location. “OP” if open; “SH” if short
0-
Firmware
Parameters
Set
Displays digit sequence; record
2-
Main Board
Firmware
Set
Displays digit sequence; record
4-
UI Firmware
Set
Displays digit sequence; record
Variable Capacity Compressor (VCC) Diagnostics (select models)
If test 38 fails, diagnose as follows:
Replace Inverter Board
→
Check at Inverter Board on
Compressor
(BLK and RED wires)
Is Inverter Board receiving 10-15
VAC and 1-5 VDC from Main
Control Board?
→
Check at Main Control Board
(BLK/WHT and RED/BLK wires)
Is Main Control Board sending
10-15 VAC and 1-5 VDC to
Inverter Board?
no
→
Check at the connector from the power cord
harness into the inverter board, located in
the machine compartment.
(PUR and WHT wires)
Is Inverter Board receiving 115 VAC
from power supply?
•
Check voltage supply.
•
Check and repair power
cord harness wiring and
connections.
no
Identify and repair damaged wires or
poor connections between Main Control
Board and Inverter Board.
yes
→
Remove inverter box from the
compressor and check resistance
across compressor winding pairs as
shown.
Is resistance across all winding
pairs equal?
Replace Compressor and
Inverter Board.
no
→
Check connections from Inverter
Board to Compressor
Are connections from Inverter
Board to Compressor intact?
yes
Identify and repair damaged
wires or poor connections
between Inverter Board and
Compressor.
no
VCC Resistance Check
Check resistance between terminals 1 and
2, 2 and 3, 3 and 1.
If all resistances are equal,
compressor is operative.
Replace Main Control Board.
no
yes
yes
yes
Error Codes
Special Modes
Display
Interpretation
Mode
Display
Activate/Deactivate
(press for up to 10 sec. simultaneously)
FZ
FF
FZ
FF
--
OP Open FF Thermistor Manual Defrost
d
F
+ and - / same to deactivate
OP
--
Open FZ Thermistor Display / Showroom
77
77
٨ and - / Power-on-Reset (POR)
--
SH Shorted FF Thermistor Sabbath
Sb
Sb
٧ and + / same to deactivate
SH
--
Shorted FZ Thermistor System Diagnostic
No FF or FZ dis-
play, all UI LEDs on.
٨ and ٧/ + to deactivate
SY
CF
UI to Main Control
Board communication
failure; on start up
Notes:
• Always check for pin back-outs, pinched or damaged wires before replacing
components.
• Determine whether failure is caused by the component, main control board or
wiring.
Contact TID before replacing main control board.
• Refer to Service Manual for additional information.
SY
CE
UI Main Control
Board communication
error; after a period
in operation
SY
EF Evaporator Fan
Failure
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
FREEZER ICE MAKER INFORMATION
(Where Applicable)
Test Cycling: Remove cover by inserting screwdriver in notch at bot-
tom and prying cover from housing. Use screwdriver to rotate motor
gear counterclockwise until holding switch circuit is completed. All
components of ice maker should function to complete the cycle.
Water Fill Volume: The water fill adjustment screw will change the
fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is
102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the
fill volume must be checked.
TU
R
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment