FASS FA F16 150G User Manual
Page 10
E.
Slid the FASS pump into mounting brackets with the weep hole facing down. Torque (4) bolts to 110
inch pounds.
D. Using thread tape, install the 2 10-300 into the “T” & “E” ports. Torque to 40 ft./lbs. Connect the male
end of the wire harness to the female electrical connector on the FASS pump. Reconnect the battery.
Turn key to the “On” position. With the FASS pump on, squirt a liberal amount of WD-40 or other
lubricant into the “T” port. This procedure will “wet” the Gerotor and allow for better suction during
initial priming.
Note: Do Not Put Thread Tape on Flare of Fitting
This manual is related to the following products:
See also other documents in the category FASS Water equipment:
- T D07 095G (20 pages)
- T D07 220G (20 pages)
- T D08 095G (19 pages)
- T D08 220G (21 pages)
- T D09 095G (19 pages)
- T D10 125G (20 pages)
- T D02 095G (19 pages)
- T F17 125G (21 pages)
- T F17 200G (21 pages)
- T F17 220G (21 pages)
- T F16 095G (19 pages)
- T F16 220G (20 pages)
- T F16 260G (20 pages)
- T F14 125G (21 pages)
- T F14 200G (21 pages)
- T F14 220G (21 pages)
- T C11 095G (20 pages)
- T C10 095G (20 pages)
- T C10 220G (21 pages)
- T 095G (23 pages)
- T 220G (23 pages)
- T 260G (23 pages)
- T UIM 150G (23 pages)
- T UIM 220G (23 pages)
- T UIM 260G (23 pages)
- T 080G (23 pages)
- T 125G (23 pages)
- T 200G (23 pages)
- FA D05 095G (16 pages)
- FA D05 220G (16 pages)
- FA D05 260G (16 pages)
- FA D07 095G (16 pages)
- FA D07 220G (16 pages)
- FA D07 260G (16 pages)
- FA D08 095G (16 pages)
- FA D08 220G (18 pages)
- FA D08 260G (18 pages)
- FA D09 095G (15 pages)
- FA D10 125G (18 pages)
- FA D10 220G (19 pages)
- FA D10 240G (19 pages)
- FA D02 095G (15 pages)
- FA F17 125G (19 pages)
- FA F17 200G (19 pages)
- FA F17 220G (19 pages)