beautypg.com

English, Use control panel – Camlink Professional photo studio CL-STUDIO30 User Manual

Page 6

background image

6

English

Use

Control panel

1 2 3 4 5

CELL

LAMP

SYNC

TEST

SOUND

~220-240V/50Hz

6

8

9
5

4

5

3

2

12 11

13 14

1

10

7

1. Mains plug connection

2. On/off switch

3. Lamp selection button

4. Lamp indicator

5. Power control buttons (lamp)

6. Power control buttons (flash tube)

7. Display

8. Sync plug connection

9. Sync button

10. Sync indicators

11. Sound button

12. Sound indicator

13. Test button

14. Test indicator

1

• Connect the mains plug to the mains plug connection.

2

• To switch on the device, set the on/off switch to the “I“ position.

• To switch off the device, set the on/off switch to the “O“ position.

3/4

• Press the lamp selection button 1x to adjust the lamps synchronously.

The upper lamp indicator is on. The lower lamp indicator is off.

• Press the lamp selection button 2x to adjust the lamps independently.

The upper and lower lamp indicator are on.

• Press the lamp selection button 3x to switch off the lamp.

The upper and lower lamp indicator are off.

5/7

• Press the upper power control button to increase the power output of the lamp.

The display shows the power output.

• Press the lower power control button to decrease the power output of the lamp.

The display shows the power output.

6/7

• Press the power control button “+“ to increase the power output of the flash tube.

The display shows the power output.

• Press the power control button “-“ to decrease the power output of the flash tube.

The display shows the power output.

8/9/10

• Insert the sync plug of the remote control into sync plug connection.

• Press the sync button 1x to set the standard sync mode. Sync indicator 1 comes on.

• Press the sync button 2x to set the 0.5s-delay sync mode. Sync indicator 2 comes on.

• Press the sync button 3x to set the 2x-trigger delay sync mode. Sync indicator 3 comes on.

• Press the sync button 4x to set the 3x-trigger delay sync mode. Sync indicator 4 comes on.

• Press the sync button 5x to set the 4x-trigger delay sync mode. Sync indicator 5 comes on.

11/12

• Press the sound button to activate a buzz sound during charging.

The sound indicator comes on.

• Press the sound button again to deactivate a buzz sound during charging.

The sound indicator goes off.

13/14

• Press the test button to start testing the operation of the flash light.

The test indicator comes on.

• Press the test button to stop testing the operation of the flash light.

The test indicator goes off.