The Amico Automatic Gas Manifolds are designed in accordance with the current revision of NFPA 99.
There are three categories of Amico manifolds depending upon the delivery pressure. The following gas types are avail-
able for each delivery pressure:
55 PSI Delivery Pressure
•
Oxygen, Nitrous Oxide, Medical Air, Carbon Dioxide, Helium, Argon
100 PSI Delivery Pressure
•
Oxygen, Medical Air, Carbon Dioxide
170 PSI Delivery Pressure
•
Nitrogen, Instrument Air
Delivery (Line) Pressure - (see NOTE above)
Delivery (Line) Pressure
55 PSI
100 PSI
170 PSI
Intermediate Pressure - Ready Bank
100 PSI
200 PSI
200 PSI
Dome Bias Pressure
55 PSI **
50 PSI
50 PSI
Intermediate Pressure - In Use Bank
150 ± 10 PSI*
250 ± 10 PSI
250 ± 10 PSI
Intermediate Relief Valve
350 PSI
350 PSI
350 PSI
Line Regulator Relief Valve
75 PSI
150 PSI
225 PSI
Maximum Inlet Pressure
3000 PSI
3000 PSI
3000 PSI
* The intermediate pressure valve of the “In Use” bank is dependent upon the dome bias pressure. Variations from the 55
PSI delivery pressure will affect the intermediate pressure reading.
** Same as delivery pressure.
- Artwall (6 pages)
- Ceiling Column Manual Retractable (16 pages)
- Ceiling Column Motorized Retractable (20 pages)
- Ceiling Column Rigid (Stationary) (12 pages)
- Ceiling Column Rigid LITE (Stationary) (12 pages)
- Recessed Console Unit (8 pages)
- Freedom Series Recessed (12 pages)
- Freedom Series Surface Mounted (8 pages)
- LDR Headwall (8 pages)
- Majestic Series Double Tier Recessed Headwall (6 pages)
- Majestic Series Double Tier Surface Mounted Headwall (8 pages)
- Majestic Series Single Tier Surface Mounted Headwall (6 pages)
- Majestic Series Single Tier Surface Mounted Headwall (8 pages)
- Majestic Series Single Tier Recessed Headwall (8 pages)
- Noble Custom Cabinet (7 pages)
- Power Column (7 pages)
- Regal Series Recessed Vertical Flatwall (8 pages)
- Regal Series Surface Mounted Vertical Flatwall (7 pages)
- Security Recessed Console Box Assembly (12 pages)
- Surface Mount Console Unit (6 pages)
- Hydraulic Patient Transfer Stretcher (S-H-300) (20 pages)
- Hydraulic Patient Transfer Stretcher (S-H-300) (11 pages)
- AHM Monitor Arms (Adjustable Height) (34 pages)
- Barcode Dock Mount (15 pages)
- Condor Adjustable Height Channel (20 pages)
- Condor Lite Fixed Height Channel (31 pages)
- Condor Lite Fixed Height Channel (12 pages)
- Falcon Combo Arm (44 pages)
- Light-Duty Monitor Arm (20 pages)
- Monitor Roll Stands (12 pages)
- CSA Duplex RED Horizontal Tank Mount (36 pages)
- NFPA Duplex CCD Horizontal Tank Mount (51 pages)
- NFPA Duplex RED Horizontal Tank Mount (40 pages)
- 12" Floor Pedestal (8 pages)
- 2 in 1 Alarm System (56 pages)
- Alarm Valve Combo Unit (32 pages)
- Alert-3 LCD Alarm (28 pages)
- Automatic Cryogenic Liquid Solenoid Manifold (32 pages)
- Ball Valve (8 pages)
- British Standard Outlet (18 pages)
- British Standard Outlet Slim (18 pages)
- Chemetron Compatible Ceiling Column Outlet (24 pages)
- Chemetron Retro-fit Gas Control Panel (4 pages)
- Dome Loaded Manifold CSA (44 pages)
- Dome Loaded Manifold Nema-4 NFPA (44 pages)