Names and functions of the parts (operation panel), E-11 – Compaq iP-60E User Manual
Page 12
E-11
Names and Functions of the Parts (Operation Panel)
7
1
8
5
12
6
9
10
4
3
2
11
A Check of the Supplied Items and the Names of the Parts
5. INPUT SELECT Buttons
These buttons select the input source.
OHP
→ PC1 → PC2 → VIDEO → OHP →...
See Page E-23.
6. PORTRAIT/TRANSFER Button
During OHP selection: The orientation of the projection
screen will be changed. The changed screen will be dis-
played adjusted to its width. See Page E-23, or the image
can be transferred by holding the button down for a long
time. See Page E-28.
During PC selection: When a USB cable is connected,
the images stored internally are transferred to the person-
al computer. See Page E-26, 28.
7. BRIGHTNESS Buttons
These buttons adjust the brightness of the projection
screen. See Page E-26.
8. SCROLL Buttons
Sets the selection of the item or the adjustment value at
the menu screen. Moves the zoom position during a zoom
display. Moves the pointer when the pointer is being dis-
played.
See Pages E-24, 25, 28, 29 and 32.
9. FREEZE/CAPTURE Button
Makes the projection screen image into a still image. In the
OHP mode, the image is stored in internal memory as a
thumbnail.
See Page E-26.
10. FREEZE OFF Button
Cancels the still image mode.
This is used when checking the projection screen while
moving the document.
See Page E-27.
11. FREEZE LED
This LED is lit green during the still image display and is lit
orange at the time the display is frozen (or captured). The
LED goes off when the still image condition is cancelled.
12. ZOOM Buttons
These buttons adjust the magnification of the projection
screen. See Page E-24.
1. POWER Button
Switches the power of the projector on or off (standby
mode).
• Only this button is effective when the projection lamp is
off.
See Page E-21.
2. ON/STANDBY LED
Lit red during standby and lit green when the projection
lamp is on. See Page E-21.
3. LAMP/COVER LED
Lit green during projection. Lit red when the air filter or
lamp unit cover is not in place.
• At the time of the projection lamp lighting operation, the
LED flashes for about 6 seconds and then lights green.
• The LED will be lit red when there has been a lamp
lighting error.
• When the projection lamp is off, the LED flashes green
for 60 seconds and then goes off. (When the projection
lamp is off, the flashing interval will be longer than with
other flashing conditions. )
• When the projection lamp has been used in excess of
1,400 hours, the LED flashes red; when use exceeds
1,500 hours the LED is lit a steady red.
See Page E-40.
4. TEMP LED
When the internal temperature has risen excessively, the
LED flashes red for 10 seconds, then is lit a steady red.
See Page E-40.
LED List
LED State
Significance
AC power OFF
Standby
Standby to start of projection
End of projection to standby
Projecting
Fan cover open
Lamp cover open
Lamp burned out
Lamp usage exceeds 1,500 hours
Temperature fault
Fan fault
Lamp usage exceeds 1,400 hours
Abnormal temperature warning
Normal
condition
Alarm
sounding
Power
has been
switched
OFF be-
cause of the
alarm
TEMP
Off
Off
Off
Off
Off
Red
Off
Flashing red
LAMP/COVER
Off
Off
Flashing green
Green
Red
Off
Flashing red
Green
ON/STANDBY
Off
Red
Green
Green
Red
Red
Green
Green