Great Plains YP1225A-24TR 24 Twin Row 30-Inch Quick Start User Manual
Page 4

Quick Setup Guide for IntelliAg Model YP1225 30” Twin Row Air Pro
11001-1592-201108
©2011 DICKEY-john Corporation
Specifi cations subject to change without notice.
TABLE G:
Accessory
Setup
Default Value/
Value to Enter Instructions/Defi nitions
Hopper Setup
# of Hoppers
1 (base unit)
1 more (optional)
# of hopper sensors connected to each module (4 sensors maximum).
# of hopper data items for each listed module and the Hopp #’s value
will automatically populate if Auto Confi g is used to confi gure installed
sensors.
Logic Level
Active Lo
Sets the active state to low signifying that an alarm is generated if
the sensor’s output is in a low state. Use this setting if the connected
sensor outputs a low condition when empty similar to the DICKEY-john
hopper sensor.
Alarm Delay
5 sec
Controls the delay time between the detection of a high/low hopper
alarm condition and the generation of the resulting alarm. The value is
entered in seconds.
Channel
Assigns hopper sensor to channel.
RPM Setup
High Alarm
(fan speed)
3000 rpm
Sets the RPM value at which a high RPM warning error is generated.
Low Alarm
(fan speed)
1800 rpm
Sets the RPM value at which a low RPM warning error is generated.
High Alarm Delay
10 sec
Establishes the delay between the detection of a high RPM alarm con-
dition and the resulting alarm display. The value is entered in seconds.
Low Alarm Delay
10 sec
Establishes the delay between the detection of a low RPM alarm con-
dition and the resulting alarm display. The value is entered in seconds.
RPM Constant
3 pulses/rev
Number of pulses per sensor revolution.
RPM Filter
0
Filters the signal out of the RPM sensor.
Disable Control
on Low Alarm
Disabled
Allows for disabling of all control channels if the RPM value of the
selected sensor falls below the low alarm level setting.
STEP 10: Accessory Sensor Setup
Hopper Assignment
At the Main Work screen, press the Next Page button
.
Press the Module Confi guration button
to display the Module Confi gura-
tion screen.
At the Module Confi guration screen, press the Hopper Assign button
.
Press Hopper Set button
.
Enter desired values using Table G as reference.
RPM Assignment
At the Module Confi guration screen, press the Acc Assign button
.
Press the RPM Setup button
.
Enter # of RPMs, if required. NOTE: There must be at least 1 RPM sensor
confi gured before the RPM Setup button appears on the screen.
Enter desired RPM values using Table G as reference.
1.
2.
3.
4.
5.
1.
2.
3.
4.
TABLE F:
Speed
Set
Default Value/
Value to Enter
Instructions/Defi nitions
Source
Digital Frequency
Select CAN Ground if radar is connected to ISO tractor cab harness.
Select Digital Frequency if radar or hall-effect is connected to WSMT
actuator harness.
Gspd Constant
2546
Input based on pulse count produced by the ground speed sensor
over 400’ distance. See Operator’s manual for calibration instructions.
Shutoff Speed
0.5 mph
Set desired minimum ground speed allowed before the system shuts
off.
Minimum
Override
2.0 mph
Set to operate when actual ground speed falls below the designated
value. Control will operate at this speed until actual ground speed
rises above minimum override speed or actual speed drops below
shutoff.
Master Sw
Timeout
10
Set to desired number of seconds system shuts off if the master
switch is turned on and there is no ground speed. Toggle master
switch to restart the system and turn off alarm.
Gspd Fail Alarm
Delay
5
Set to desired number of seconds alarm sounds after the ground
speed is zero and seed fl ow continues. (Monitor only)
Precharge Ground
Speed
0
Set to the desired speed the system will use when a precharge time
has been enabled for a control channel. Refer to Table C1: Planter
Control Setup for Precharge Time. This setting will only display when
a Precharge Time has been entered.
Implement Lift
Enabled
Implement lift switch, when enabled, displays an implement lift indica-
tor on the Main Work screen indicating implement lift position as up
or down. Control channels can be turned on and off without using the
master switch.
STEP 9: Speed Set Calibration Setup
At the Main Work screen, press the Speed Set button
.
Enter desired values using Table F as reference.
Press the Work Screen button
when ground speed calibration confi gu-
rations are complete to return to the Main Work screen.
1.
2.
3.
4