Quick Setup Guide for IntelliAg Model YP1625 15” Air Pro
11001-1600-201108
©2011 DICKEY-john Corporation
Specifi cations subject to change without notice.
TABLE G:
Speed Set
Default Value/
Value to Enter
Instructions/Defi nitions
Source
Digital Frequency
Select CAN Ground if radar is connected to ISO tractor cab harness. Select
Digital Frequency if radar or hall-effect is connected to WSMT actuator har-
ness.
Gspd Constant
2546
Input based on pulse count produced by the ground speed sensor over 400’
distance. See Operator’s manual for calibration instructions.
Shutoff Speed
0.5 mph
Set desired minimum ground speed allowed before the system shuts off.
Minimum
Override
2.0 mph
Set to operate when actual ground speed falls below the designated value.
Control will operate at this speed until actual ground speed rises above mini-
mum override speed or actual speed drops below shutoff.
Master Sw
Timeout
10
Set to desired number of seconds system shuts off if the master switch is
turned on and there is no ground speed. Toggle master switch to restart the
system and turn off alarm.
Gspd Fail Alarm
Delay
5
Set to desired number of seconds alarm sounds after the ground speed is zero
and seed fl ow continues. (Monitor only)
Precharge
Ground Speed
0
Set to the desired speed the system will use when a precharge time has been
enabled for a control channel. Refer to Table C1: Planter Control Setup for
Precharge Time. This setting will only display when a Precharge Time has
been entered.
Implement Lift
Enabled
Implement lift switch, when enabled, displays an implement lift indicator on
the Main Work screen indicating implement lift position as up or down. Control
channels can be turned on and off without using the master switch.
STEP 9: Speed Set Calibration Setup
At the Main Work screen, press the Speed Set button
.
Enter desired values using Table G as reference.
Press the Work Screen button
when ground speed calibration
confi gurations are complete to return to the Main Work screen.
1.
2.
3.
TABLE H:
Accessory
Setup
Default Value /
Value to Enter Instructions/Defi nitions
Hopper Setup
# of Hoppers
1 (base unit)
1 more (optional)
# of hopper sensors connected to each module (4 sensors maximum). # of
hopper data items for each listed module and the Hopp #’s value will automati-
cally populate if Auto Confi g is used to confi gure installed sensors.
Logic Level
Active Lo
Sets the active state to low signifying that an alarm is generated if the sensor’s
output is in a low state. Use this setting if the connected sensor outputs a low
condition when empty similar to the DICKEY-john hopper sensor.
Alarm Delay
5 sec
Controls the delay time between the detection of a high/low hopper alarm
condition and the generation of the resulting alarm. The value is entered in
seconds.
Channel
Assigns hopper sensor to channel.
RPM Setup
High Alarm
(fan speed)
3000 rpm
Sets the RPM value at which a high RPM warning error is generated.
Low Alarm
(fan speed)
1800 rpm
Sets the RPM value at which a low RPM warning error is generated.
High Alarm Delay
10 sec
Establishes the delay between the detection of a high RPM alarm condition
and the resulting alarm display. The value is entered in seconds.
Low Alarm Delay
10 sec
Establishes the delay between the detection of a low RPM alarm condition
and the resulting alarm display. The value is entered in seconds.
RPM Constant
3 pulses/rev
Number of pulses per sensor revolution.
RPM Filter
0
Filters the signal out of the RPM sensor.
Disable Control
on Low Alarm
Disabled
Allows for disabling of all control channels if the RPM value of the selected
sensor falls below the low alarm level setting.
STEP 10: Accessory Sensor Setup
Hopper Assignment
At the Main Work screen, press the Next Page button
.
Press the Module Confi guration button
to display the Module
Confi guration screen.
At the Module Confi guration screen, press the Hopper Assign button
.
Press Hopper Set button
.
Enter desired values using Table H as reference.
RPM Assignment
At the Module Confi guration screen, press the Accessory Assignment
button
.
Press the RPM Setup button
. NOTE: There must be at least 1
RPM sensor confi gured before the RPM Setup button appears on the
screen.
Enter desired values using Table H as reference.
1.
2.
3.
4.
5.
6.
7.
8.
4