4. O
PERATION
W
HEATHEART
- G
RAIN
A
UGERS
4.4. M
AINTENANCE
4" G
ALVANIZED
U
TILITY
20
30645 R0
• If the problem is plugging, clear as much of the grain as possible using a
piece of wood, vacuum cleaner or other tool (not your hands) before
restarting auger. Do not reach in and use your hands.See “Auger Drive
and Lockout Procedure” on page 17.
4.4. MAINTENANCE
Proper maintenance on the auger mean a longer life for the machine, better
efficiency and safer operation. Please follow the guidelines below.
4.4.1. G
ENERAL
M
AINTENANCE
P
ROCEDURES
Important:
Use only genuine Wheatheart replacement parts or equivalent. Replacement
parts such as intake guards, pulley guards, PTO driveline shields, winches, and
lift cables must meet ASAE standards or serious injury may result. Use of
unauthorized parts will void warranty. If in doubt, contact Wheatheart or your
Wheatheart dealer. Do not modify any auger components.
NOTICE
Starting the auger under full load may result in damage to
unit. Be sure there is no blockage.
Area
Maintenance Procedure
Frequency
General
While auger is in use, observe the operation checklist
on page 17.
Daily
General
If for any reason a part becomes damaged, replace it
immediately. If possible, lower auger to replace parts.
Regularly
Drive Belt
Check and replace if frayed or damaged.
Ensure tension is correct under load (correct tension is
the lowest at which the belts will not slip under peak
load conditions)
Frequently
Auger Supports
Inspect (cracked welds, proper configuration of
supports, bent/damaged pieces, etc.)
Frequently
Motor Cover
Protect motor from weather by covering.
During off sea-
son or when not
in use.