Bias Adjustment


Insert the meter plug into the bias jack. Adjust for 150 mA to 160 mA reading on volt ohm meter or DC
current meter. Re-adjust the setting after the amp has warmed up for 10 minutes. Remove the bias
adjustment plug and enjoy the music!

Adjust bias pot until meter reads 160mA