13

SEND SIgNAL

LED

Versa•Touch2 oPeraTion

Fan Control

To start the fan. Press the selected speed button to run the fan at the desired speed.

LO=Low speed mED=medium speed HI=High speed

To turn off the fan. Press the

FAN OFF button.

Airflow Direction

To reverse the airflow press the

REVERSE button. Reverse operates at any speed whether fan

is on or off. The fan returns to its set speed after reversing.

Light Control

Turn the light on or off independently from the fan by pressing the

LIgHT button. Keep

pressing the button in excess of 0.7 seconds, it becomes a dimmer. The light varies from

‘bright’ to ‘dim’ over approximately 8 seconds. This sequence will reverse the light when it

reaches the brightest or dimmest level if you continue to hold the

LIgHT button. Release

the button when the desired level is reached.

memory Feature

The last light function and fan speed will resume when power is turned back on.

Auto Resume

Quick (pressing less than 0.7 seconds) on/off operation of the

LIgHT button maintains the

desired brightness level set previously.

Versa•Touch2 IF FAN DOES NOT WORK

If the fan is not functioning after installation:

Step 1. Check to make sure that batteries are installed correctly

in the control.

Step 2. Turn the power off to the fan (from the circuit breaker)

for at least 5 seconds.

Step 3. Turn the power back on (at the circuit breaker) and push

the Hi, Med, and Low buttons–in that order–within 20 seconds.

Step 4. The fan should now function properly.

Versa•Touch2 CHANgINg FREQUENCY SETTINg

you will only have to change the dip switch settings in the remote if

you are using more than one fan in the same area and want to control

them separately.

Step 1. At the circuit breaker or fuse box, turn the power off for the

fan you want to change.
Step 2. Open the battery door of the Versa•Touch control and remove

the batteries.
Step 3. Change the dip switch settings, assuring that they are different

from the previously installed Versa•Touch fan.
Step 4. Re-install the batteries and the battery door on the control.
Step 5. At the circuit breaker or fuse box, turn the power back on for

the fan whose frequency you are changing.
Step 6. Within 20 seconds of restoring power, push the Hi, Med, and

Lo buttons (in that order).

note: All fans leave the factory set to ‘00000’.

WITHIN 20 SECONDS OF

TURNINg THE FAN ON,

PRESS IN THIS ORDER TO

SET NEW FREQUENCY:

1. HI

2. mED

3. LO

1

2

3

CIRCUIT BREAKER

OR FUSE BOX

PRESS IN THIS ORDER TO SET NEW

FREQUENCY:

1. HI 2. mED 3. LO

DIP SWITCH

SET TO ‘01001’

DIP SWITCH

SET TO ‘10000’

Versa•Touch 2

CONTROL

(BACK)

note: You may want to label your controls to

assure you do not mix them up.

WARNINg: Do not turn the power off at the circuit breaker,

then back on, for the previously installed Versa•Touch 2

fan(s), as you may inadvertantly change the frequency set-

tings for it as well.

LO

mED

HI

LIgHT

FAN

STOP

REVERSE

1

2

3

V

ersa

•T

ouch

2

®