6
Installation
Your extractor can be used to filter and recycle the air within 
your kitchen, or to extract the air outside. When extracting air 
to the outside, the unit can be vented as shown in the diagram 
below. Note that we recommend the use of ducting with a 
diameter of 150mm. Ducting with diameters of 100mm or 
120mm may be used, but performance will be reduced.
When installing this appliance over a CDA hob, the clearance 
between the extractor and the hob must be equal to or 
exceed 450mm. This instruction overrides the instructions 
supplied with the CDA hob. (The height should be measured 
from the top of the hotplates or burners)
Where the extractor is to be installed above a non-CDA hob, 
the instructions supplied with the hob may dictate that the 
height required above the hob is greater than 450mm.
IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED 
WITH THE HOB, THE MINIMUM DISTANCE BETWEEN 
THE HOB AND EXTRACTOR MUST BE AT LEAST 
760mm.
Fitting your extractor to the wall
Before commencing the installation open front panel. Hold 
the panel as shown in figure 8 and lift upwards and out.
Fig. 7
Fig. 6
Fig. 8
min 45cm
B
A
1
2