Majestic, Fireplaces power venting system – CFM Corporation PVS-1 User Manual
Page 3

3
Majestic
®
Fireplaces Power Venting System
51810
3. Vent System Termination
 Before installing Power Venter, determine location of 
vent system termination.
4. Location of the Fan
 To keep the noise level to a minimum, the fan should 
be located as far from the appliance as possible. 
A storage cupboard, or laundry area are preferred 
locations. Permanent access for inspection and 
servicing must be provided.
5. All portions of the vent system under positive pres-
sure during operation (on the outlet side of the 
Power Venter) shall be designed and installed so as 
to prevent leakage of flue or vent gases into a build-
ing.
General Code Requirements
The exit terminal shall be so arranged that flue gases 
are not directed so as to jeopardize the safety of 
people, overheat combustible structures or enter 
buildings, and that proper clearances are maintained. 
Always consult your local codes and authorities. In 
the absence of such codes follow the current installa-
tion codes for gas burning appliances CSA-B149.1 in 
Canada or ANSI Z223.1/NFPA 54 in the US.
Also see Diagram A - Vent Termination Locations.
Power Venter Specifications
Electrical
Motor voltage .................................... 115
Control Circuit Voltage ........................24
Hz ........................................................60
RPM ................................................3000
Watts ...................................................95
Amps ................................................1.26
Thermal Protection ............................Yes
Mechanical
Shaded Pole Motor ...........................Yes
Int. Fan Cooled ................................. yes
Shaft Diameter (inch) ........................313
Bearings .............................. Sleeve Type