Stove and chimney connector clearance charts – Vermont Casting 2479 User Manual
Page 13
13
Dutchwest Non-Catalytic Convection Heater
30002291
Stove and Chimney Connector Clearance Charts
Stove Clearance
Side
Rear
3
Corner
Side
Rear
3
Corner
No heat shields
(A) 21”
(B) 26”
(C) 21¹⁄₂”
(D) 8”
(E) 20”
(F) 16¹⁄₂”
(533 mm)
(660 mm)
(546 mm)
(203 mm)
(508mm)
(419 mm)
Rear exit,
(G) 23”
(H) 13”
N/A
N/A
N/A
N/A
flue collar heat shields
(584 mm)
(330 mm)
Top exit
1,2
, flue collar
(K) 15”
(L) 15”
(M) 12¹⁄₂”
(N) 8”
(O) 12”
(P) 10”
Single-wall connector
(381 mm)
(381 mm)
(318 mm)
(203 mm)
(305 mm)
(254 mm)
w/connector heat shield
Right Side
Right Side
and right side heat shield
Only
Only
Top exit
1
, flue collar
(K) 20”
(L) 16”
(M) 12¹⁄₂”
(N) 8”
(O) 14¹⁄₂”
(P) 12”
heat shield,
(508 mm)
(406 mm)
(318 mm)
(203 mm)
(368 mm)
(305 mm)
Double wall connector
Chimney Connector Clearance: To Rear Wall Combustible Surface
Single-wall connector
20”
14”
No connector heat shield
(508 mm)
(356 mm)
Single-wall
2
connector
w/connector heat shield
9”
6”
& flue collar heat shield
(229 mm)
(152 mm)
Double-wall connector
10”
8¹⁄₂”
& flue collar heat shield
(254 mm)
(216 mm)
Front Clearance to Combustibles:
(All Installations)
48” (1219 mm)
Model 2479 Large Convection Heater
UNPROTECTED SURFACES
PROTECTED SURFACES
Corner
Corner
Parallel Installations
Installations Parallel Installations
Installations
1. Shielding for a top exit stove must include a flue collar shield to protect the area behind the flue collar.
2. Chimney connector heat shields must extend exactly 24” (610 mm) above the flue collar of the stove.
3. Dimension is to the top plate of the stove, not the back wall of the stove.
Important:
When choosing an installation utilizing the side loading door located on the left side of the stove, follow the
minimum dimensions given in the Stove and Chimney Connector Chart on Page 4 and the Minimum Dimen-
sions for Noncombustible Floor Protectors given on Page 9, Figure 12.
For operation of the side loading door, the minimum clearances on the left side of the stove for usable opera-
tion is 14¹⁄₂” (368 mm) in a corner installation and 20” (508 mm) in a parallel installation.