beautypg.com

Measurement time comparison, I g-dualscan – ORBIT FR G-DualScan User Manual

Page 5

background image

130

Probe array

The probe array mechanical characteristics are limited to

• Internal diameter of 12.8 m
• Angle between the probes is 1.304°

Single-probe

Positioner series

AL–1760–1P

Bending moment

20,000 ft-lbs

2,765 kg-m

Operating load

20,000 Ibs

9,090 kg

Delivered torque

2,800 ft-Ibs

390 kg-m

Withstand torque

4,200 ft-Ibs

580 kg-m

Drive power

¾ hp

Nominal speed

0.5 rpm

Standard angle transducer format

Dual speed synchro

Standard accuracy

± 0.02°

Maximum backlash

0.05°

Mechanical characteristics

Typical ‘on the fly’ measurement

Single-probe set-up

Frequency

Number of measured

Measurement

frequencies

time (in hours)

3 GHz, AUT Diameter is 3 m

10

1.2

6 GHz, AUT Diameter is 5 m

10

3.8

Typical ‘on the fly’ measurement

Multi-probe set-up

Frequency

Number of measured

Measurement

frequencies

time (in hours)

3 GHz, AUT Diameter is 3 m

10

0.1

6 GHz, AUT Diameter is 5 m

10

1.5

Measurement time comparison

10 dBi AUT 20 dBi AUT 30 dBi AUT

PEAK GAIN ACCURACY

0.2 - 0.4 GHz

± 1.5 dB

± 1.46 dB

± 1.46 dB

0.4 - 1 GHz

± 0.9 dB

± 0.86 dB

± 0.86 dB

1 - 18 GHz

± 0.5 dB

± 0.44 dB

± 0.42 dB

PEAK GAIN REPEATABILITY

± 0.3 dB

± 0.3 dB

± 0.3 dB

- 10 dB SIDELOBES ACCURACY

0.4 - 0.8 GHz

± 0.8 dB

± 0.5 dB

± 0.4 dB

0.8 - 1 GHz

± 0.7 dB

± 0.5 dB

± 0.4 dB

1 - 6 GHz

± 0.7 dB

± 0.5 dB

± 0.4 dB

6 - 18 GHz

± 0.7 dB

± 0.5 dB

± 0.4 dB

10 dBi AUT 20 dBi AUT 30 dBi AUT

- 20 dB SIDELOBES ACCURACY

0.4 - 0.8 GHz

± 2.6 dB

± 0.8 dB

± 0.5 dB

0.8 - 1 GHz

± 2.1 dB

± 0.7 dB

± 0.5 dB

1 - 6 GHz

± 2.1 dB

± 0.7 dB

± 0.5 dB

6 - 18 GHz

± 2.1 dB

± 0.7 dB

± 0.5 dB

- 30 dB SIDELOBES ACCURACY

0.4 - 0.8 GHz

-

± 2.6 dB

± 0.8 dB

0.8 - 1 GHz

-

± 2.1 dB

± 0.7 dB

1 - 6 GHz

-

± 2.1 dB

± 0.7 dB

6 - 18 GHz

-

± 2.1 dB

± 0.7 dB

*Specifications given according to the following assumptions:
- The standard deviation of the reference data is 0.1dB
- The S11 & the directivity of the reference antenna are the same as those of the AUT
- Absorbers in the anechoic room are AEP-36 from AEMI.
- The given peak gain accuracy values are for 0 dB AUT efficiency

System specifications*

5

I G-DualScan