Technical data/scope of delivery, Di r, Technical data – Unger DI400 User Manual
Page 13: General view / scope of delivery

1
2
3
9
5
6
7
8
4
10
11
ENGLISH
www.ungerglobal.com
12
13
H
i
F
lo
™ Di r
esin
F
ilter
Technical Data/scope of delivery
2. Technical Data
Factor
DI400
DI800
Efficiency / capacity x 1°dH x 1l
40000
80000
Max. efficiency (l) at 10°dH
4000
8000
Shipping weight (kg)
30
53
Operating weight (kg)
40
76
Flow rate / h
up to 600l
up to 600l
Container height (cm)
100
120
Diameter (cm)
20
25
Overall height (cm)
125
125
Perm. pressure (bar)
10
10
Max. water temp. (°C)
30
30
Min. water temp. (°C)
2
2
Pure water qual. (ppm)
<10
<10
3. General view / scope of delivery
1. Water outlet to pole – standard garden
hose “female”
2. Shut-off valve water outlet
3. Pressure tank – resin cartridge
4. Pressure gauge (manometer)
5. Water supply from the tap.
Standard garden hose „male“
6. Shut-off valve water supply
7. Stainless steel base plate
8. Fine filter (for prefiltering)
9. Water flow rate counter
10. Robust trolley (stainless steel).
11. TDS counter for incoming and outgoing
water