beautypg.com

Dyna-glo propane forced air construction heaters, Specifications – Vermont Casting ANSI Z83.7-2000 User Manual

Page 3

background image

Page 2

WARNING: Not for use with ductwork.

SPECIFICATIONS:

Dyna-Glo Propane Forced Air Construction Heaters

The heater is designed and approved for use as a construction heater under ANSI Z83.7., CSA2.14

It is hard to anticipate every use which may be made of this heater.

CHECK WITH YOUR LOCAL

FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.

Other standards govern the use of fuel gases and heat producing products in specific applications.
Your local authority can advise you about these.

IMPORTANT: Read this user's manual carefully and completely before trying to operate or
service this heater. Improper use of this heater can cause serious injury or death from fire,
explosion and carbon monoxide poisoning.

This is a direct-fired forced-air construction heater for either indoor or outdoor use. Its intended use
is primarily the temporary heating of buildings or structures under construction, alteration or repair.
All the products of combustion generated by the heater are forced through the heater and released
into the area being heated. This heater operates at approximately 98%+ combustion efficiency but
still produces a small amount of carbon monoxide. Humans can tolerate small amounts of carbon
monoxide for short periods. Carbon monoxide can build up in a heated space and failure to provide
adequate ventilation could result in poisoning or death.

Model No.

RMC-FA40DLX

RMC-FA40A

-

RMC-FA(50A)

RMC-FA100DLX

RMC-FA100A

RMC-FA150DLX

RMC-FA150A

Input Rating

40,000 Btu/hr
-

30,000 Btu/hr
50,000 Btu/hr

70,000 Btu/hr
100,000 Btu/hr

120,000 Btu/hr
150,000 Btu/hr

Type of Gas

Propane

Propane

Propane

Propane

Gas Supply Pressures
to Regulator Maximum Cylinder Pressure

Cylinder Pressure

Cylinder Pressure

Cylinder Pressure

Minimum (for purpose
of Input Adjustment)

5psig

5psig

5psig

5psig

Manifold Pressure

11” W.C.

10” W.C.

9.5” W.C

8” W.C.

Gas Consumption

1.9lbs/hr
3.3lbs/hr

2.3lbs/hr
1.4lbs/h

4.6lbs/hr
3.3lbs/h - 5.6lbs/hr

7lbs/hr
5.6lbs/hr

Electrical Input

120V, 60Hz, 1 Ø

120V, 60Hz, 1 Ø

120V, 60Hz, 1 Ø

120V, 60Hz, 1 Ø

Amperage

Unload
Load

0.35A
0.63A

0.58A
0.75A

0.6A
0.8A

0.6A
0.8A

Fan

Unload
Load

3550rpm
3000rpm

3570rpm
3300rpm

3580rpm
3300rpm

3580rpm
3300rpm

Ignition

Piezo/Manual Spark Continuous Spark

Continuous Spark

Continuous Spark

Spark Gap

0.16”

0.16”

0.16”

0.16”

Size (L x W x H)

18.1” x 7.7” x 12.8” 18.1” x 7.7” x 12.8” 25.12” x 9” x 15.5”

25.12” x 9” x 15.5”

Weight

15.2lbs (6.9kg)

15.2lbs (6.9kg)

22.7lbs (10.3kg)

22.7lbs (10.3kg)