Troubleshooting symptom possible cause remedy, Troubleshooting – Triton TRA 001 User Manual
Page 11
10
GB
Troubleshooting
TROUBLESHOOTING
SYMPTOM
POSSIBLE CAUSE
REMEDY
Router will not operate
No supply of power
Check that power is available at source
Brushes worn or sticking
Disconnect power, open brush caps and ensure
brushes move freely in the holders. Check whether
the brushes require replacing - see Page 9
Switch is faulty
Go to www.tritontools.com for your nearest Triton
Approved Service Agent
Motor components faulty or short
circuited
Go to www.tritontools.com for your nearest
Triton Approved Service Agent
Router runs slowly
Blunt or damaged cutter
Re-sharpen or replace cutter
Variable speed set low
Increase variable speed setting
Motor is overloaded
Reduce pushing force on router
Makes an unusual sound
Mechanical obstruction
Go to www.tritontools.com for your nearest Triton
Approved Service Agent
Armature has shorted sections
Go to www.tritontools.com for your nearest Triton
Approved Service Agent
Excessive vibration
Bent cutter shank
Replace cutter
Heavy sparking occurs inside motor
housing
Brushes not moving freely
Disconnect power, remove brushes, clean or
replace
Armature short circuited or open circuited
Go to www.tritontools.com for your nearest
Triton Approved Service Agent
Commutator dirty
Go to www.tritontools.com for your nearest Triton
Approved Service Agent
Micro adjuster “clicks”
Plunge lock engaged
Release plunge lock lever
Plunge selector button is engaged
Disengage the plunge selector button. Refer to
'Handle Winder Plunge'
Reached end of adjustment range.
Reset the router
Plunge lock lever not locking
Plunge lock lever not correctly positioned
Reposition plunge lock lever as described in 'Free
Plunge'
Shutter on power switch not releasing
Router is plunged to full depth - in collet
lock position
Reduce plunge depth
Can’t plunge to collet lock position
Power switch “On”
Switch power 'Off'
330165_Z1MANPRO1(with Japanese).indd 10
21/07/2014 09:49