Table Mounted Operation / Maintenance

• Fitting and operating this router on a Router Table should be

carried out in accordance with the literature supplied with your

Router Table

• While this product was designed for efficient and convenient

operation on most router tables, it is particularly suited for use

with the Triton Router Table RTA300

• Router adjustments are made easily using the unique features

of this product. When mounted in a compatible table, the Table

Height Winder (24) will control the cut height when connected

to the Table Height Winder Connection Point (25) through a hole

in the router table surface

REMOVING THE PLUNGE SPRING
IMPORTANT
: You MUST remove the plunge spring before fitting

WARNING: Always disconnect from the power supply before

carrying out any maintenance/cleaning.
• Any damage to the router should be repaired and carefully

inspected before use by qualified repair personnel. Service or

maintenance performed by unqualified personnel could result

in a risk of injury

• Servicing should only be carried out by authorised Triton

Repair Centres using original Triton replacement parts. Follow

instructions carefully and refer to ‘Troubleshooting’ for problem

identification and advice. Use of unauthorised or faulty parts

may create a risk of electric shock or injury

• Triton Precision Tools will not be responsible for any damage

or injury caused by unauthorised repair of the router or by

mishandling of the tool

CLEANING
• Keep your tool clean at all times. Dirt and dust will cause

internal parts to wear quickly, and shorten the machine’s

service life. Clean the body of your machine with a soft brush,

or dry cloth. If available, use clean, dry, compressed air to blow

through the ventilation holes

TABLE MOUNTED OPERATION

MAINTENANCE

this router into a router table:
1. Set the router at the top of its plunge range and engage the

Plunge Lock Lever (10)

2. Loosen the small screw next to the Plunge Spring Access Cap

(11)

3. Holding the plunge spring access cap firmly (so that the spring

will not shoot upwards when released), twist the cap anti-

clockwise to remove it

4. Remove the spring and store in a

safe place

5. Replace the plunge spring cap

and re-tighten the screw

NOTE: Ensure the plunge spring

is refitted before using the router

free-hand.

BRUSH REPLACEMENT
The carbon brushes are a

consumable item which should be

inspected periodically and replaced

when worn. Failure to do so may

result in damage to the motor.
1. With the router disconnected

from power, unscrew the Brush

Caps (2) located on the front and

rear of the motor

2. Remove the brushes by pulling carefully on the protruding

springs

3. If either of the brushes is worn to less than 6mm long, they

must both be replaced using genuine Triton replacement

brushes - available from Authorised Triton Repair Centres

POWER CORD REPLACEMENT
If the supply cord needs replacing, the task must be carried out by

the manufacturer, the manufacturer’s agent, or an authorised Triton

service centre, in order to avoid a safety hazard.

STORAGE
• Store this tool carefully in a secure, dry place out of the reach

of children

DISPOSAL
Always adhere to national regulations when disposing of power

tools that are no longer functional and are not viable for repair.
• Do not dispose of power tools, or other waste electrical and

electronic equipment (WEEE), with household waste

• Contact your local waste disposal authority for information on

the correct way to dispose of power tools

330165_Z1MANPRO1(with Japanese).indd 9