MODEL IQ CHEMICAL HEATER OPERATION / MAINTENANCE MANUAL

PAGE 7

Figure 2-1

Note: The heater has no provision for monitoring or controlling flow rates
or provisions to turn off flow to the heater during a leak alarm. It is
recommended that the user incorporate a separate interlock to isolate
flow and power from the heater in the event of an alarm.

2.3.b Element Over-Temperature Protection

The Trebor IQ chemical heater is supplied with a temperature sensor(s)
located on the heater element. The element temperature sensor(s) must
be used with an interlock to ensure the element temperature does not
exceed 250°C. Note, two types of sensors are available

– thermocouple

and RTD. See Section 7 for wiring instructions.

2.3.c Liquid Over-Temperature Protection

The maximum liquid temperature (T

max

°C) can be estimated from the

element temperature (T

e

°C), heater power rating (P - i.e. 3-kW, 4-kW, 6-

kW, etc.) and duty cycle (duty %). T

e

= T

max

+ P * duty * 16.1

Example 1: Given a maximum allowable liquid temperature of 140°C, a

heater rated at 6 kW and a 100% duty cycle, the maximum
element temperature limit is:

T

e

= 140°C + (6)*(1.00)*(16.1)