Jumper configuration, Txd control, Rxd control – Connect Tech BlueStorm Multi-port Serial Adapter User Manual

Page 9: Rxd ± termination/bias, Txd ± termination, Auto 485

background image

BlueStorm/LP Installation Guide, Connect Tech Inc.

Revision 0.05

9

Jumper Configuration

In the following example, the four RS-422/485 ports are set as follows: port 1 is set for half
duplex, port 2 is set for half duplex; port 3 is set for full duplex, and port 4 is set for multi-drop
slave.

Figure 4: Jumper configuration example for 4 port RS-232/422/485 models

TxD Control
Install this jumper to enable the RS-485 transmitter only when sending data. This mode is useful
for half-duplex operation when only one device is allowed to send data at a time. If the jumper is
not installed, the transmitter will always drive the line to an idle state when not sending data.
RxD control
Install this jumper to enable the RS-485 receiver only when NOT transmitting data. This is
useful for half-duplex operation to prevent the transmitting device from receiving its own data as
it sends. If this jumper is not installed, the receiver is always enabled and ready to receive data.
RxD ± Termination/Bias
Install this pair of jumpers to enable a 150 ohm terminator across the RxD+ and RxD- pins for
the corresponding port. A biasing network is also enabled that drives the receiver to an inactive
or safe mode. The receiver can still receive data from another device and the biasing helps to
prevent the reception of data generated by noise on the transmission line. The two jumpers for
RxD termination/bias must be installed and removed as a pair.
TxD ± Termination
Install this jumper to enable a 150 ohm resistor across the TxD+ and TxD- pins of the
corresponding port.
Auto 485 (2 port RS-422/485 models only):
Install this jumper to tri-state the RS-485 transmitters when the computer boots or is reset. Note
that this jumper can be overridden by driver/software with RS-485 support. For example, the
RS-485 modes in the Windows control panel will take precedence over this jumper.
Note also that Auto 485 is a single jumper. The second site is not in use. See

Figure 1

for the

location of this jumper.

Half Duplex

and

Multi-drop Slave

modes require you to select the appropriate

mode via software. Please refer to the

readme.txt

files found in the appropriate

directories on the BlueStorm/LP CD.

JD1
JD2
JD3
JD4
JD5

JA

JD1
JD2
JD3
JD4
JD5

JB

Port 1

Port 2

JD1
JD2
JD3
JD4
JD5

JC

Port 3

JD1
JD2
JD3
JD4
JD5

JD

Port 4

TxD control
RxD control
RxD

± Termination/Bias

RxD

± Termination/Bias

TxD

± Termination