Tests and certifications – TERRALUX TLM-R08A User Manual
Page 5

5
TERRALUX TLM-R08A Product Specification – Subject to change without notice
WWW.TERRALUX.COM
5/23/2014
Tests and Certifications
Product Safety Certifications
•
UL Standard 8750: LED Light Sources for Use In Lighting Products
•
CSA C22.2 No. 250.0-08: Canadian National Standard for Luminaires
Radio Frequency Emissions
•
FCC Part 15, Unintentional Radiators Class A.
Sec 107, Conducted Emissions - 0.15MHz – 30MHz
Sec 109, Radiated Emissions - 30 MHz – 8000MHz
•
Industry Canada Notice ICES-003: Class A Digital Apparatus
Reduction of Hazardous Substances
(RoHS)
European Council Directive 2002/95/EC, (including amendments
2005/618/EC, 2005/717/EC and 2005/747/EC) on the restriction of
certain hazardous substances in electrical and electronic equipment.
Electro-Static Discharge
•
± 4kV and ± 6kV contact discharge to all exposed conductive (25
discharges each polarity)
•
±8kV and ± 10kV air gap discharges to all non-conductive surfaces
(25 discharges each polarity)
Power Factor
>0.8
Shock
Operating - 82 G peak, 2 ms; Half sine, 1 shock per second 20 shocks per
axis, both directions – total 120 shocks
Vibration
Operating - Random PSD Spectrum G, 1.0G RMS, 10-2000 Hz. 30
minutes per axis 3-500 Hz., 0.50 g peak, swept sine @ ½ octave/min per
axis
Non-Operating - Random PSD, 5 G RMS, 15 minutes per axis
5-500-5 Hz, 1.0 g peak, Swept Sine @ ½ Octave per minute, per axis.
Drop Test
Free fall drop from a distance of 1 meter onto a non-resilient test floor.
Six (6) drops onto each of the three surfaces (top, bottom, side).
Operation checked after each set of 10 impacts.
Shipping / Transit
International Safe Transit Association (ISTA) Project 3A.
Operating Temperature
-40°C to +55°C, 0 to 95% R.H. / 153 hr.
Lumen Maintenance
L70 =60,000hr per IES TM-21-11 (Based on LED Manufacturer’s
measurement per IES LM-80-08 @ 10.000hrs).
Long Term Operation
MTBF >1.7 million hours
Reliability Demonstration Test (RDT)
Demonstrate the reliability required to meet 97.5% survivability at 5
years, with 95% confidence.
Input Voltage Range
12V AC +/- 10%: 9.6V – 14.4V