beautypg.com

Oilless compressors, Troubleshooting chart (continued) – Campbell Hausfeld FP204100 User Manual

Page 6

background image

6

Oilless Compressors

www.chpower.com

troubleshooting Chart (Continued)

Symptom

Possible Cause(s)

Corrective action

Compressor runs continuously and safety

valve opens as pressure rises

1. Defective pressure switch

2. Defective safety valve

1. Replace pressure switch

2. Replace safety valve with genuine

replacement part

Excessive starting and stopping

1. Excessive condensation in tank

2. Loose connections (fittings, tubing, etc.)

1. Drain more often

2. Check all connections with soap and water

solution. If a leak is detected, tighten.
Or remove fitting and apply pipe tape to
threads and reassemble.

notes

This manual is related to the following products: