4 pressure-temperature diagram, 5 flow rates, kv100 (cv), Pressure-temperature diagram – Richter HVR Series Bellows-Sealed Valves User Manual
Page 5: Flow rates, kv100 (cv), Series hv, hvr, 4 pressure-temperature diagram 1.5 flow rates, Installation and operating manual, Kv100 (cv)
Installation and Operating Manual
Series HV, HVR
9520-050-en
Revision 01
TM 6128 MPE/Wm
Page 5
Edition
04/2005
Seat and packing nut
DN
Seat
Tightening
torque
Packing nut
Tightening
torque
[mm] [inch]
[Nm] [in-lbs]
[Nm] [in-lbs]
15 --
3
26,5
7
62
20 --
3
26,5
7
62
25 1
6
26,5
7
62
40 1½
12
106
7
62
50 2
16
141,5
7
62
65 --
16
141,5
7
62
80 3
28
248
7
62
100 4
30
265,5
7
62
1.4 Pressure-temperature diagram
1.5 Flow rates,
kv100 (Cv)
HVR with control plug
Nom.
diameter
K
v100
Cv
Seat -
in mm
[mm] [inch]
8
8
8
8
8
14 14 14 14 14 14 15 20 25 30
15
--
m
3
/h
USgpm
0,05
0.06
0,10
0.12
0,20
0.23
0,50
0.58
0,80
0.93
4
4,7
20
--
m
3
/h
USgpm
0,05
0,06
0,10
0.12
0,20
0.23
0,50
0.58
0,80
0.93
4
4,7
25
1
m
3
/h
USgpm
0,05
0,06
0,10
0.12
0,20
0.23
0,50
0.58
0,80
0.93
1,20
1.40
4
4,7
7
8,2
11
12,8
Nom.
diameter
K
v100
Cv
Seat -
in mm
mm] [inch]
15 20 25 30 40 50 65 80 96
40
1½
m
3
/h
USgpm
4
4,7
7
8,2
11
12,8
15
17,5
28
32,6
4
4,7
7
8,2
11
12,8
50
2
m
3
/h
USgpm
7
8,2
11
12,8
15
17,5
28
32,6
42
48,9
65
--
m
3
/h
USgpm
7
8,2
11
12,8
15
17,5
28
32,6
42
48,9
80
3
m
3
/h
USgpm
15
17,5
28
32,6
42
48,9
65
75,7
100
117
100
4
m
3
/h
USgpm
42
48,9
65
75,7
100
117
155
180