beautypg.com

1 technical data, 1 intended use, Technical data – Richter HVR Series Bellows-Sealed Valves User Manual

Page 3: Intended use, 1technical data, Series hv, hvr, Installation and operating manual

background image

Installation and Operating Manual

Series HV, HVR

9520-050-en

Revision 01

TM 6128 MPE/Wm

Page 3

Edition

04/2005

1

Technical data

Manufacturer:

Richter Chemie-Technik GmbH
Otto-Schott-Str. 2
D-47906 Kempen
Telephone : +49 (0) 2152 146-0
Fax:

+49 (0) 2152 146-190

E-Mail :

richter-info@richter-ct.com

Internet:

http://www.richter-ct.com

Designation :

Globe shut-off or control valve with safety stuffing box
and bellows to German Clean Air Regulations (TA-
Luft) as well as interchangeable seat and plug.
Series

HV

version with on-off plug

HVR

version with control plug

Control characteristics for HVR to DIN EN 60534,
equal percentage, linear, on-off, rangeability 25:1.
V-plug, rangeability 100:1
Tightness tested to DIN EN 12266-1
Face to face alternatively:

EN 558-1 basic series 1, ISO 5752 series 1

with flanges DIN EN 1092-2, type B

(ISO 7005-2 Type B) PN 16 or flanges drilled to

ASME (ANSI) B16.5 Class 150
ASME (ANSI) B16.10, column 21, Class 150 with
flanges ASME (ANSI) B16.5 Class 150, raised
face

Testing for valves DIN EN 12266-1, 12266-2.

Materials :

Body material: Ductile cast iron EN-JS 1049 to DIN
EN 1563 (0.7043 DIN 1693) or ASTM A395
Lining material: PFA or FEP

on request : conductive design

Temperature range :

See pressure-temperature diagram in Section 1.5.

Operating pressure:

Standard bellows

up to 10 bar

Heavy-duty bellows

up

to

16 bar

Hastelloy C-bellows

up to 16 bar at 180 °C

Ball valve sizes in mm :

DN 15, 20, 25, 40, 50, 65, 80, 100
1", 1½", 2", 2½", 3" 4" in inch

Weight:

Nom.

Size

15 20 25 40 50 65 80 100

ASME

--

--

1“

1½“

2“

--- 3“ 4“

ca. kg

7

7

12 17 20 22 49 55

Installation position:

The direction of flow is marked by an arrow cast into
the body.
See Sections 5.2.

Dimensions and individual parts:

See sectional drawing in Section 9.

Wear parts:

Seat, plug, bellows

Options :

Heavy-duty bellows DN 25 - 100 (1" - 4")
For permeating media and elevated pres-
sures/temperatures
Hastelloy bellows
For special applications (e.g. extreme permeation)
Alarm or flushing connection
For higher safety requirements

1.1 Intended use

Richter globe shut-off or control valves of the series
HV, HVR are pressure containing components in
accordance with the Pressure Equipment Directive
(PED) for the passage and shut-off of fluids. The
valves are suitable for vapours, gases and non-boiling
liquids of group 1 according to the PED and have a
corrosion-resistant plastic lining.
Solids can lead to increased wear, damage to sealing
surfaces or to a reduction in the service life of the
valve.
The operator must carefully examine in the event of
operating data other than those provided whether the
designs of the valve, accessories and materials are
suitable for the new application (consult the
manufacturer).

This manual is related to the following products: