beautypg.com

11 dimensional drawing mvp/f, Dimensional drawing mvp/f, Series mv/f, mvm/f, mvp/f, mvmp/f – Richter MVMP/F Series Diaphragm Valves with Actuator User Manual

Page 20: Dn l d d1 h h1 h (stroke)

background image

Series MV/F, MVM/F, MVP/F, MVMP/F

Page 20

9510-050-en

Revision 02

TM 7669

Edition 10/2009

10.11 Dimensional drawing MVP/F

DN

L

D

D1

H

H1

h (stroke)

Weight

*

[mm]

[inch]

[mm]

[inch]

[mm]

[inch]

[mm]

[inch]

[mm]

[inch]

[mm]

[inch]

[kg]

[lb]

15

130

(5.12)

95

(3.74)

68

(2.68)

6.4

(0.25)

3

(6.61)

20

150

(5.91)

105

(4.13)

89

(3.5)

12

(0.47)

4,2

(9.26)

25

160

(6.3)

115

(4.53)

92

(3.62)

12

(0.47)

4,8

(10.58

40

200

(7.87)

150

(5.91)

126

(4.96)

18

(0.71)

9,1

(20.06)

50

230

(9.06)

165

(6.5)

130

(5.12)

27

(1.06)

12

(26.46)

80

310

(12.2)

200

(7.87)

172

(6.77)

40

(1.57)

21,3

(46.96)

100

350

(13.78)

220

(8.66)

193

(7.6)

40

(1.57)

29,7

(65.48)

150

480

(18.9)

285

(11.22)

275

(10.83)

60

(2.36)

56,2

(123.9)

Flange connecting dimensions:
DIN EN 1092-2, type B (ISO 7005-2, type B) PN 16

or flanges drilled to ASME B16.5 Class 150

*

without actuator

Dimensions D1 and H1 vary depending on the
actuator manufacturer.