OPERATING INSTRUCTIONS
Airflow direction control
 Adjust the air flow direction properly otherwise, it might 
 cause discomfort or cause uneven room temperatures.
 Adjust the horizontal louver using the remote controller.
 Adjust the vertical louver manually.
 To set the vertical air flow(Up-Down) direction
 Perform this function while the unit is in operation.
 Keep pressing the SWING button on the remote 
 controller to move the louver to the desired 
 direction. The readjusting angle of the horizontal 
 louver is 6 for each press.
 
To set the horizontal air flow direction (left - right)
 Adjust the vertical louver manually using the lever on the
 left or right side of the vertical louver arm (Depending on
 model). Take care not to catch fingers on the fan, horizontal
 louver or to damage vertical louvers. When the air
 conditioner is in operational and the horizontal louver is in
 a specific position, move the lever at left (or right, depending
 on model) end of the air outlet to the desired position.
To automatically swing the air flow direction (up - down)
Perform this function while the air conditioner is in operation.
 Keep pressing the SWING button without releasing for more 
 than 2 seconds on the remote controller, the horizontal louver 
 will swing up and down automatically. 
 To stop the function, press the DIRECTION/SWING button 
 again.
 
The SWING button will be disabled when the air conditioner is not in 
operation(including when the TIMER ON is set).
Do not operate the air conditioner for long periods with the air flow 
direction set downward in cooling or dry mode. Otherwise, condensation 
may occur on the surface of the horizontal louver causing moisture to drop 
on to the floor or on furnishings.
Do not move the horizontal louver manually. Always use the SWING
button. If you move this louver manually, it may malfunction during 
operation. If the louver malfunctions, stop the air conditioner once and
restart it.
When the air conditioner is started immediately after it was stopped, the 
horizontal louver might not move for approximately 10 seconds.
Open angle of the horizontal louver should not be set too small, as 
COOLING or HEATING performance may be impaired due to too 
restricted air flow area.
Do not operate unit with horizontal louver in closed position.
When the air conditioner is connected to power (initial power), the 
horizontal louver may generate a sound for 10 seconds, this is a normal 
operation.
CAUTION
!