To insert the cable, align the key
ways on the extension cable with the
circular receptacle on the ballast.
Rotate the locking ring until it clicks
into the lock position.

Lamps can operate as far as 75 feet
from the ballast. (3 x 25ft extensions)











WARNING!

1) ALWAYS TURN OFF THE BALLAST BEFORE connecting or

disconnecting Lamps, Harnesses or Extension Cables.

2) Use only with Sine wave inverters. Do not operate on SCR

dimmers.

3) If powering the ballasts through a Dimmer Pack set the

Dimmer to Non-Dim Mode.









The 120 VAC Ballast requires 110 to 130 Volts AC 50/60 Hertz on an
earth grounded circuit; the 230 VAC Ballast requires 220 to 240 Volts
AC on an earth grounded circuit. The electronic Ballast operates at a
high frequency of 25KHz. It is dead–quiet, instant–on and lightweight.

The Ballast operates remote from the fixture. Connect the Extension
cable to the Ballast and the Lamp Harness. After the lamps are
properly installed the Ballast can be turned on.

Cold Temperature Operation
The Select Ballast series is designed to operate at temperatures from
14F to 122F (–10C to +50C). In cold temperatures, the Ballast may
not strike the lamp (s) instantly. Switch the Ballast to OFF, wait seven
seconds and try again. If the Ballast does not strike after two or three
attempts, turn off the Ballast, check that the Extension and Harness
connections are secure and re-strike. Once operating for a few
minutes, the Lamps should re-strike instantly.