beautypg.com

4 technical data, Technical data, 4technical data – Gossen Mavolux 5032C/B User Manual

Page 7

background image

GOSSEN Foto- und Lichtmeßtechnik GmbH

7

4

Technical Data

Characteristics MAVOLUX 5032C

Most Important Error Limits MAVOLUX 5032C

Light Detector

silicon photodiode with
V(

λ

) filter per DIN 5032 part 7,

class C

Error Limits

per DIN 5032, part 7, class C

Meas. Quantity

Measuring Range

Resolution
in lx

Resolution
in fc

in Lux (lx)

in footcandles (fc)

Illumination

I

0.1

199,9

0.01

19.99

0.1

0.01

I I

1

1

999

0,1

199.9

1

0.1

I I I

10

19

990

1

1

999

10

1

I V

100

199 900

10

19

990

100

10

in Candela/m² (cd/m²)

in footlambert (fL)

in cd/m²

in fL

Luminance
(with luminance
attachment
for cd/m

2

or fL)

I

1

1

999

0.1

199.9

1

0.1

I I

10

19

990

1

1

999

10

1

I I I

100

199

900

10

19

990

100

10

I V

1 000

1 999 000

100

199 900

1000

100

Characteristics

Allowable Error
Limits per
DIN 5032 Class C

Actual Error
MAVOLUX 5032C

V(

λ

) Matching

9%

7.5%

True Cosine Evaluation

6%

2%

Linearity

5%

1.5%

Adjustment Error

2%

1%

Total Error

20%

15%