beautypg.com

Model bw3 – Bryant BW1 User Manual

Page 11

background image

—11—

SPECIFICATIONS

UNIT SIZE

042

075

112

150

187

225

Sections—Fine Grain Cast-Iron

No.

2

3

4

5

6

7

GAS CONTROLS — INTERMITTENT PILOT

Gas Valve

Honeywell

Inlet Size

In.

1/2 FPT

Pilot Assembly

Honeywell

Spark Generator

Honeywell

Burners—Stainless/Titanium Alloy

No.

1

2

3

4

5

6

Burner Orifice—Drill Size Natural

32

34

34

34

34

34

CONTROLS

Limit Control Range

°

F

180–240

Pressure/Temperature Gage

Psig

0–60

°

F

60–260

Pressure Relief Valve Setting

Psig

30

Circulator Relay—Aquastat

Honeywell (Factory Installed)

CIRCULATOR

Taco

Model

007

Full Load Amps

0.70

Flange Size FPT

In.

1-1/4

Model BW3 Gas-Fired Induced-Combustion Water Boilers
are the answer to energy-efficient residential hydronic
heating. They provide fast, almost instant, heat quietly and
economically.
These boilers provide quality design in a small, compact unit
easily installed in a basement, garage, or utility room. They
can be installed on a combustible floor when an optional
combustible floor kit is used.
The design of model BW3N is CSA and A.G.A. certified for
use with natural gas and is convertible to propane gas with
accessory kit.

FEATURES

RANGE OF CAPACITIES

—Six sizes ranging from 42,500 through

225,000 Btuh input.

COMPLETELY PACKAGED

—Each boiler is completely assembled,

including all controls (except room thermostat). All necessary wiring is
factory installed. The boiler is ready for gas, water, room thermostat,
and electrical power connections as shipped.

VENTING

—This boiler can be vented into any approved chimney or

Type B-1 vent. Common-venting with an existing water heater is
acceptable in vertical vent systems. See the Installation Instructions
for common venting requirements. The induced-combustion design
also eliminates the need for a vent damper.

THERMAL-PIN CAST-IRON SECTIONS

—These sections speed

heat transfer from the flue gases to the boiler water, with faster ther-
mostat response, providing greater comfort and economy.

TITANIUM COMPOSITE BURNERS

—Provide quiet operation,

corrosion resistance, and improved combustion efficiency. Propane
convertible with accessory kit.

CONTROLS

—An automatic gas valve and intermittent pilot provide

quiet, dependable operation of the burners. Factory-installed safety
components provide maximum safety against overheating, pressure
buildup, and low-water operation.

INSULATED CASING

—Fully insulated with fiberglass for maximum

operating efficiency and economy.

SECTIONS TESTED

Each section is hydrostatically tested to

50 psig. Individual sections are tested to 125 psig at factory.
Assembled sections are tested to 75 psig at the factory. The
maximum allowable pressure is 50 psig for hot water boilers.

UNIT CONVERTIBLE

—The Boiler is listed for power venting with field

controls power venting kit.

WARRANTY

—The cast-iron sections are covered by a non-prorated

20-year warranty on the entire assembly. Circulator pump covered by
3-year warranty. All other parts are covered by a 1-year limited
warranty.