c) Minimum regulation of the hob burners:

Turn the tap to minimum;

Remove the knob and adjust the regulation screw,
which is positioned in or next to the tap pin, until the
flame is small but steady.
NB.: In the case of liquid gas, the regulation screw
must be screwed in all the way.

Check that the flame does not go out when you turn
the tap quickly from high to low.

d) Regulating the primary air of the burners: the primary

air of the burners does not need to be regulated.

Burner and Nozzle Specifications

Table 1

Liquid Gas

Natural Gas

Burner

Diameter

(mm)

Thermal Power

kW (p.c.s.*)

By-Pass

1/100

Nozzle

1/100

Flow*

g/h

Nozzle

1/100

Flow*

l/h

Nozzle

1/100

Flow*

l/h

Nominal Reduced

(mm)

(mm)

***

**

(mm)

(mm)

Fast
(Large)(R)

100

3.00

0.7

41

86

218

214

116

286

143

286

Semi Fast
(Medium)(S)

75

1.90

0.4

30

70

138

136

106

181

118

181

Auxiliary

(Small)(A)

55

1.00

0.4

30

50

73

71

79

95

80

95

Supply

Pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20
35

37
25
45

20
17
25

13

6,5

18

*

At 15°C and 1013 mbar- dry gas

**

Propane

P.C.S. = 50,37 MJ/Kg

***

Butane

P.C.S. = 49,47 MJ/Kg

Natural

P.C.S. = 37,78 MJ/m

3

S

S

R

A

K6 G52S/R

Important
On completion of this operation, replace the old rating
sticker with one indicating the new type of gas used. This
sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in compli-
ance with current standards regarding “regulators for chan-