beautypg.com

Warning, Maintenance and lubrication schedule – Braun MILLENIUM 5 User Manual

Page 15

background image

Page 3

Maintenance and Lubrication Schedule

Maintenance and

lubrication procedures

must be performed as

specified by an

authorized service

technician. Failure to

do so may result in

serious bodily injury

and/or property

damage.

Proper maintenance is necessary to ensure safe,

troublefree operation. Inspecting the lift for any wear,

damage or other abnormal conditions should be a part

of all transit agencies’s daily service program. Simple

inspections can detect potential problems.

The maintenance and lubrication procedures specified

in this schedule must be performed by a Braun autho-

rized service representative at the scheduled intervals

according to the number of cycles.

Braun dual parallel arm lifts are equipped with hard-

ened pins and self-lubricating bushings to decrease

wear, provide smooth operation and extend the service

life of the lift.

When servicing the lift at the recommended intervals,

inspection and lubrication procedures specified in

the previous sections should be repeated. Clean the

components and the surrounding area before apply-

ing lubricants. LPS2 General Purpose Penetrating

Oil is recommended where Light Oil is called out.

Use of improper lubricants can attract dirt or other

contaminants which could result in wear or damage

to the components. Platform components exposed to

contaminants when lowered to the ground may require

extra attention.

Lift components requiring grease are lubricated during

assembly procedures. When these components are

replaced, grease must be applied during installation

procedures. Specified lubricants are available from

The Braun Corporation (part numbers provided above).

All listed inspection, lubrication and maintenance

procedures should be repeated at “750 cycle” intervals

following the scheduled

“4500 Cycles” mainte-

nance. These intervals

are a general guideline

for scheduling mainte-

nance procedures and

will vary according to

lift use and conditions.

Lifts exposed to severe

conditions (weather, envi-

ronment, contamination,

heavy usage, etc.) may

require inspection and

maintenance procedures

to be performed more

often than specified.

Maintenance Indicator: The Lift Ready green LED

mounted on top of the pump cover will begin to blink

after every 750 cycles. The blinking LED will not affect

the functions of the lift, but is a reminder to complete

necessary maintenance and lubrication.

Once the lift has been serviced, fully stow the lift. Once

stowed, press the UP button on the hand pendant and

the Floor Level Set button on the back side of the pump

cover until the Lift Ready green LED stops blinking.

Discontinue lift use immediately if maintenance and

lubrication procedures are not properly performed, or if

there is any sign of wear, damage or improper opera-

tion. Contact your sales representative or call The

Braun Corporation at 1-800-THE LIFT

®

. One of our

national Product Support representatives will direct you

to an authorized service technician who will inspect your

lift.

Outer barrier hinge pivot points (2)

Outer barrier latch (pivot/slide points)

Outer barrier latch lever pivot points

Lift-Tite

latches (tower pivot points - 2)

Lift-Tite

latch gas (dampening) spring pivot

points (2 springs - 4 points)

Inspect Lift-Tite

latches and gas springs for wear

or damage (bent, deformed or misaligned), posi-

tive securement (external snap rings) and proper

operation

Inspect outer barrier for proper operation

Inspect outer barrier latch for proper operation,

positive securement, and detached or missing

spring

Apply Light Oil - See Lubrication Diagram

Apply Light Oil - See Lubrication Diagram

Apply Light Oil - See Lubrication Diagram

Apply Light Oil - See Lubrication Diagram

Apply Light Oil - See Lubrication Diagram

Resecure, replace defective parts or otherwise

correct as needed. Note: Apply Light Grease to

Lift-Tite

latch tower pivot point if replacing latch.

Correct or replace defective parts.

Correct or replace defective parts and/or relubri-

cate. See Lubrication Diagram

750

Cycles

WARNING