Models X366GGVX (X36 6 00 X) [M3Y0GTU4X(2 or 5)A]

Burner Position Injector Gas Pressure

Max Rate

Min Rate

By‐pass

diam.

[mm.]

Type

[i.w.c.]

[BTU/h]

[W] [BTU/h]

[W] diam.

[mm]

Auxiliary Front

R 0,90

NG

4” 3400

996

900 264

Regulated

0,54

LP

(Propane)

11”

3400

996

900

264

0,29

Semi‐Rapid

Rear L & C

1,18

NG

4”

6100

1787

1500

439

Regulated

Front C

0,70

LP (Propane)

11”

6100

1787

1500

439

0,36

Rapid Rear

R 1,55 NG 4”

10400

3047

2500

732

Regulated

0,92

LP

(Propane)

11”

10400

3047

2500

732

0,47

Front L Inner

0,80

NG

4”

2800

820

900

264

Regulated

Dual Burner

0,49

LP (Propane)

11”

2800

820

900

264

0,29

Front L Outer

N°2 x 1,15

NG

4”

12000 3516

4500

1318

Regulated

N°2 x 0,70

LP (Propane)

11”

12000 3516

4500

1318

0,65

Oven Oven 2,00 NG 4”

16000

4688

4000

1172

Regulated

downside

1,15

LP

(Propane)

11”

16000

4688

4000

1172

0,60

Broiler

Oven

1,90

NG

4”

14500 4248

Only Max Only Max

No by‐pass

upside

1,10

LP (Propane)

11”

14500 4248

Only Max Only Max

No by‐pass




Models X365GGVX (X36 5 00 X)
[M3W0GTU4X(2 or 5)A]

Burner Position Injector Gas Pressure

Max Rate

Min Rate

By‐pass

diam.

[mm.]

Type

[i.w.c.]

[BTU/h]

[W] [BTU/h]

[W] diam.

[mm]

Auxiliary Front

R 0,90

NG

4” 3400

996

900 264

Regulated

0,54

LP

(Propane)

11”

3400

996

900

264

0,29

Semi‐Rapid

Rear L and R

1,18

NG

4”

6100

1787

1500

439

Regulated

0,70

LP

(Propane)

11”

6100

1787

1500

439

0,36

Rapid Front

L 1,55 NG 4”

10400

3047

2500

732

Regulated

0,92

LP

(Propane)

11”

10400

3047

2500

732

0,47

Centre

Inner

0,80 NG 4”

2800

820

900

264

Regulated

Dual Burner

0,49

LP (Propane)

11”

2800

820

900

264

0,29

Centre Outer

N°2 x 1,15

NG

4”

12000 3516

4500

1318

Regulated

N°2 x 0,70

LP (Propane)

11”

12000 3516

4500

1318

0,65

Oven Oven 2,00 NG 4”

16000

4688

4000

1172

Regulated

downside

1,15

LP

(Propane)

11”

16000

4688

4000

1172

0,60

Broiler

Oven

1,90

NG

4”

14500 4248

Only Max Only Max

No by‐pass

upside

1,10

LP (Propane)

11”

14500 4248

Only Max Only Max

No by‐pass