Electrical connection – Bertazzoni X365GGVGI User Manual
Page 12
12
ELECTRICAL CONNECTION
This unit is manufactured for a polarized,
grounded 120 volt/60 Hz, 16 amp system.
Electric power consumption is about 150 W.
The minimum of 102 VAC is required for proper
operation of gas ignition systems.
The circuit must be grounded and properly
polarized.
The unit is equipped witth a SJT power cord. In
case of replacement, the power cord shall be
replaced with one of the same type, size and
length.
ELECTRICAL GROUNDING
This appliance is equipped with a three‐prong
plug for your protection against shock hazard and
should be plugged directly into a properly
grounded socket. Do not cut or remove the
grounding prong from this plug.
WARNING!
ELECTRICAL SHOCK HAZARD
Disconnect electrical power at the circuit
breaker box or fuse box before installing the
appliance.
Provide appropriate ground for the appliance.
Use copper conductors only.
Failure to follow these instructions could result
in serious injury or death
CAUTION
Label all wires prior to disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Verify proper operation after servicing.
WIRING DIAGRAM