Clay Paky PIN SCAN (12Vmax 100W) User Manual
Page 3
7
• Changing fuses
To change the fuses, press the tab (8) and
pull out the fuse holder (10). Replace any
blown fuse with one of the same type and
rating as indicated on the label (10)
attached to the holder (9). Insert the fuse
holder and push in to engage the tab (8).
• Routine cleaning
To maintain the light output of the projector undiminished, parts that tend to accumu-
late dust and grease must be cleaned periodically.
To remove dirt from the reflector and filter use a soft cloth moistened with any liquid
detergent suitable for cleaning glass.
CAUTION: Do not use solvents or alcohol
IMPORTANT: isolate the projector from the electrical power supply before
commencing maintenance work of any description.
The maximum temperature on the outer surface of the projector under normal
operating conditions is 100°C (212° F).
After switching off, do not remove any part of the projector for at least 10 minutes; once
this time has elapsed, the risk of a lamp exploding is practically zero. If the lamp needs
changing, wait a further 15 minutes to avoid the risk of burns.
MAINTENANCE
4
ENGLISH
CAUTION:
- When fitting a new lamp read the manufacturer's instructions carefully.
- The lamp must always be changed without delay if damaged or deformed by heat.
•
Only use 12V halogen lamps with a maximum power of 100W made
with low pressure technology.
250 V
1A T
5 x 20
FUSE
8
9
10
TROUBLESHOOTING
5
No electrical power supply.
Check that power is available at
the mains socket and/or that fuses
are intact.
PROJECTOR DOES NOT LIGHT UP
FAULTS
PROJECTION FAULTY
REDUCED BRIGHTNESS
POSSIBLE CAUSES
CHECKS AND REMEDIES
•
•
• •
•
Lamp expended or faulty.
Change lamp (see instructions).
Deposit of dust or grease.
Clean (see instructions).
Cooling
Forced ventilation cooling system using
axial flow fan.
Housing
• Extruded die-cast aluminium.
• Epoxy powder coated finish.
Operating position
Will function in any position.
Weight and dimensions
Weight: 5.8 kg (12 lbs 12 ozs).
Power supply
• 100-120V 50/60Hz
• 200-240V 50/60Hz
Lamps
• 12V 90W (Halostar).
To be used with special Clay Paky
pencil beam parabola (2.5°).
• 12V/50-75-100W (Halospot).
Built-in reflector with different beam
apertures.
Power consumption
150VA max. (consumption varies in
relation to the lamp).
Channels
N. 3 control channels.
Inputs
• RS232/423(PMX)
• DMX512
Moving body
• Movement generated by two
microstepping motors with full micro-
processor control.
• Range of adjustment:
- PAN = 360°
- TILT = 227°
• Resolution:
- PAN = ± 1.41°
- TILT = ± 0.89°
TECHNICAL DATA
6
(9.1”)
230
(9.1”)
230
(3.4”)
86
(12.8”)
max 325
(7.5”)
190
1
1
2
3
4
5
3
1
2
• Changing the lamp: type HALOSTAR 12V max 100W with G 6.35 fitting
• Changing the lamp: type HALOSPOT 12V max 100W with G 53 fitting