Clay Paky PIN SCAN (12Vmax 100W) User Manual
Pin scan, Instruction manual english
5
PIN SCAN
• Unpacking
Open the box, remove the projector
from the packing and place it on a
flat, horizontal surface.
Unpack the standard accessories
supplied with the fixture. Inspect the
lamp change label (1) and replace it
with one of the optional language
versions if necessary.
Make sure that the label is never
removed, as it displays important
safety information.
• Connecting to the electrical power supply
The operations described in this heading must be carried out by a licensed electrician.
The projector must be wired up to the electrical power supply using the special socket
connector provided (4).
It is good policy to connect projectors to the power supply by way of dedicated
switches, so that each can be turned on and off individually from a remote station.
The projector is designed to operate at the voltage and frequency indicated on the
electrical data plate (5). Check that these two values correspond to the mains voltage
and frequency.
IMPORTANT: the projector must be connected to a power supply circuit
having a proper earth system (Class I appliance).
• Connecting the control signals
RS 232/423(PMX) - DMX 512
• Fitting the lamp
Refer to the directions for replacement of the lamp given under heading 4 MAIN-
TENANCE.
• Installing the projector
The projector can be placed on the floor on the rubber feet (2) or installed on the ceil-
ing or wall using the holes (3) in the base.
Make certain that the anchorage is stable before positioning the projector.
• Minimum distance from target objects
The projector must be positioned in such a way that
objects struck by the beam are located at least 1.3
m (4’ 3”) from the lens.
• Minimum distance of inflammable materials from any part of the fixture:
m 0.1 (4”).
The fixture may be mounted on surfaces rated normally inflammable.
IMPORTANT: For better and more reliable operation of the fixture, the ambient
temperature must not exceed 35° C (95° F). Protection factor IP 20: the fixture is
protected against penetration of solid bodies more than 12mm (0.5”) in diameter (first
digit 2), but can be damaged by spray, jet, drip or rain water (second digit 0).
2
3
1
POWER SUPPLY AND INTERFACE
2
Projectors are wired up to the controller and one to the next using two-core
screened cable and Cannon 5 pin XLR type plug/socket connectors.
To connect a DMX line, a terminating plug (8) with a 100
Ω
resistor wired between
pins 2 and 3 must be fitted to the last projector connected in series; the plug is not
required when using an RS232/423(PMX) signal.
ENGLISH
INSTALLING THE PROJECTOR
1
IMPORTANT: Read carefully. It is essential for the correct and safe use of the
equipment that erectors and operators should be fully conversant with the
information and instructions given in this manual.
INSTRUCTION MANUAL
ENGLISH
7
6
(4’ 3”)
1.3 m
12V - 100W
N
L
4
5
Mains
®
The wires must not come into contact with each other or with the metal
casing of the plug.
The casing of the plug/socket must be connected to the screen and to pin 1
of the connectors.
Having completed the operations described above, press the on/off switch (7).
Check that the lamp comes on and the auto-reset sequence starts.
SIGNAL
SCREEN
SIGNAL
5
4
3
2
1
DMX 512
SIGNAL
SCREEN
SIGNAL
RS232/423 (PMX)
1
2
3
4
5
12Vmax 100W