beautypg.com

Calculated Industries 4320 User Manual

Page 37

background image

P

OCKET

R

EFERENCE

G

UIDE

— 36

Cubic Yards of Cut/Fill

Grid Cell Method

The four corner elevations of a Grid cell
are 75.4 Feet, 77.5 Feet, 74.6 Feet, and
80.5 Feet. If the proposed elevation is 83
Feet, and the Area of the Grid is 2,000
Square Feet, what is the Volume (in Cubic
Yards) of cut or fill required for this Grid
cell?

KEYSTROKE

DISPLAY

1. Clear calculator:

o o

0.

Find average Existing Grid Elevation

2. Enter first through fourth elevation (in
Memory):

7 5 • 4 f µ

75.4

FEET

7 7 • 5 f µ

77.5

FEET

7 4 • 6 f µ

74.6

FEET

8 0 • 5 f µ

80.5

FEET

3. Find total:

® µ

308.

FEET

4. Find average:

µ

AVG 77.

FEET

Solve for Cut or Fill

5. Enter average as existing elevation:

= e

EXST 77.

FEET

(Cont’d)

M

M

M

M

M

M

M

4320PRG-E-A 6/16/04 7:53 AM Page 36