7. Set to 50º C Ambient Temperature:
(
Ambº
)
Amb
AMB° 50. ºC
8. Find Derated Wire Size:
(D/R Size)
D/R 500 Cu
WIRE SIZE
9. Reset Ambient Temperature
and Clear:
3Ø 60 Cu
0.
VolTaGe DRoP
The ElectriCalc Pro uses Resistance
values found in NEC Table 8 Chapter
9 to determine Voltage Drop, Wire
Lengths or Wire Sizes given a
maximum Voltage Drop percentage.
Finding Voltage Drop
You are installing 175 Feet of 75°C,
#8 THW branch circuit Copper
conductors to supply an 11A load on a
208V 1Ø system. What is the source
Voltage Drop at the load?
KEYSTROKE
DISPLAY
0.
1. Set to 1-Phase:
(1Ш)
1 Ш
1 Ph
2. Set to 75 º C:
(75º)
1 Ø 75
1 Ph
See also other documents in the category Calculated Industries Calculators, organizers:
- 4215 (64 pages)
- 4225-B (52 pages)
- 4225-C (52 pages)
- 44060 (134 pages)
- 4050 Metric Edition (44 pages)
- 4050 (52 pages)
- 4050 v3.1 (52 pages)
- 4050-F (52 pages)
- 4054 (52 pages)
- 4045-B (54 pages)
- 4045 (26 pages)
- 4067 Pocket Reference Guide (52 pages)
- 4067 User Guide (23 pages)
- 4065 v3.0 (108 pages)
- 4065 v3.1 Pocket Reference Guide Construction Master Pro (39 pages)
- 4065 v3.1 Pocket Reference Guide Advanced Consnruction-Math (40 pages)
- 4065 v3.1 User Guide (110 pages)
- 8030 (44 pages)
- 5025 (48 pages)
- 5065 (71 pages)
- 5070-B Pocket Reference Guide (46 pages)
- 5070-A User Guide (66 pages)
- 5070-B User Guide (66 pages)
- 4315 (56 pages)
- 4320 (51 pages)
- 4325 (53 pages)
- 4090 (123 pages)
- 4019 (40 pages)
- 4018 (38 pages)
- 4015 (84 pages)
- 4020 (39 pages)
- 4095-A Pocket Reference Guide (36 pages)
- 4095-B Pocket Reference Guide (38 pages)
- 4095-C Pocket Reference Guide (23 pages)
- 4095-A User Guide (50 pages)
- 4095-B User Guide (68 pages)
- 4095-C User Guide (65 pages)
- 4094 Pocket Reference Guide (38 pages)
- 4094 User Guide (44 pages)
- 8545 (48 pages)
- 4400 (50 pages)
- 8015 (64 pages)
- 8020 (52 pages)
- 8025 (47 pages)