beautypg.com

Page 13 – Blizzard Lighting FX SnowBlind (Rev B) User Manual

Page 13

background image

Page 13

SnowBlind™ FX Manual - Rev. B

Copyright (c) 2013 Blizzard Lighting, LLC

DMX Values In-Depth (6-Channel Mode)

Ch. Value

What It Does

1

000 <--> 255 LED 1 Intensity (0% <--> 100%)

2

000 <--> 255 LED 2 Intensity (0% <--> 100%)

3

000 <--> 255 LED 3 Intensity (0% <--> 100%)

4

000 <--> 255 LED 4 Intensity (0% <--> 100%)

5

000 <--> 255 Flash (Slow <--> Fast)

6

000 <--> 069

070 <--> 104

105 <--> 139

140 <--> 174

175 <--> 209

210 <--> 244

245 <--> 255

Static Color & Strobe

Program 1 (Channel 1 Controls Speed)

Program 2 (Channel 1 Controls Speed)

Program 3 (Channel 1 Controls Speed)

Program 4 (Channel 1 Controls Speed)

Sound Active Mode 1

Sound Active Mode 2

Troubleshooting

Symptom

Solution

Fixture Auto-

Shut Off

Check the fan in the fixture. If it is stopped or moving slower

than normal, the unit may have shut itself off due to high

heat. This is to protect the fixture from overheating. Clear

the fan of obstructions, or return the unit for service.

Beam is Dim

Check optical system and clean excess dust/grime. Also

ensure that the 220V/110V switch is in the correct position, if

applicable.

No Light Out-

put

Check to ensure fixture is operating under correct mode, IE

sound active/auto/DMX/Etc., if applicable.

Chase Speed

Too Fast/Slow

Check to ensure proper setup of speed adjustment.

No Power

Check fuse, AC cord and circuit for malfunction.

Blown Fuse

Check AC cord and circuit for damage, verify that moving parts

are not restricted and that unit’s ventilation is not obstructed

Slow Move-

ment

Verify that 220V/110V switch is in the correct position, if ap-

plicable. Also check that speed channels are set appropriately.

No Response

to Audio

Verify that the fixture is in “Sound Active” mode.

Adjust Audio Sensitivity, If Applicable.

Fixture Not

Responding /

Responding

Erraticly

Make sure all connectors are seated properly and securely.

Use Only DMX Cables and/or check cables for defects

Install a Terminator.

Reset fixture(s).

Intermittant

Lamp

Check lamp for properly installation.

Relamp, lamp may have reached end of life.