St00 - st20, Run dmx, Slav – Blizzard Lighting Vari White ProPar (Rev A) User Manual
Page 9: Temp curr
Page 9
ProPar Vari White User Manual Rev. A
Copyright (c) 2013 Blizzard Lighting, LLC
Control Panel Menu Structure
STAT
A001 - A255
Cool white intensity (0-255)
b001 - b255
Warm white intensity (0-255)
ST00 - ST20
Strobe speed (0-20)
RUN
dMX
Master/DMX mode
SLAV
Slave mode
dMX
d001 - d255
Choose the DMX address (1-255)
TEMP
CURR
Displays the current temperature
TOP
Sets the max allowed temperature
DMX Mode
Allows the unit to be controlled by any universal DMX controller.
1.) The default mode for the fixture is DMX, which appears as
dMX
on the LED
readout. Push the
choose a channel between
1
and
512
. Press to return to the previ-
ous menu option.
Master/Slave Mode:
Allows you to link up to 32 units together without a controller.
1.) Use standard DMX cables to daisy chain your units together via the DMX con-
nector on the rear of the units.
2.) Choose a unit to function as the master. The master unit must be the first
unit in the chain. Navigate the menu as follows:
Master :
RUN
dMX
3.) Select the slave function by using the
in the RUN menu on the slave units. They will react in the same as the master.
Slave:
RUN
SLAV