beautypg.com

Page 15, Page 16 – Blizzard Lighting Wash Flurry User Manual

Page 8

background image

Page 15

Flurry Wash Manual Rev. A

Copyright (c) 2010 Blizzard Lighting, LLC

DMX Channel Values (5 Channel Mode)

Channel

Channel Value

Does...

1

000 <-> 255

Pan

2

000 <-> 255

Tilt

3

000 <-> 007

008 <-> 134

135 <-> 239

240 <-> 255

Dimmer/Strobe

Closed

100%-0% Dimming

Strobe (Slow-Fast)

Open

4

000 <-> 007

008 <-> 021

022 <-> 035

036 <-> 049

050 <-> 062

063 <-> 076

077 <-> 090

091 <-> 104

105 <-> 118

119 <-> 132

133 <-> 146

147 <-> 160

161 <-> 174

175 <-> 188

189 <-> 202

203 <-> 216

217 <-> 230

231 <-> 243

244 <-> 255

Color Macros

No Function

White

Red

Green

Blue

Cyan

Magenta

Yellow

Purple

Orange

Chartruese

Pink

Brown

Gold

Crimson

Violet

Crepe

Color Change Macro #1

Color Change Macro #2

5

Reserved

Page 16

Flurry Wash Manual Rev. A

Copyright (c) 2010 Blizzard Lighting, LLC

Troubleshooting

Symptom

Solution

Fixture Auto-

Shut Off

Check the fan in the fi xture. If it is stopped or moving

slower than normal, the unit may have shut itself off due to

high heat. This is to protect the fi xture from overheating.

Clear the fan of obstructions, or return the unit for service.

Beam is Dim

Check optical system and clean excess dust/grime. Also

ensure that the 220V/110V switch is in the correct position,

if applicable.

No Light Output Check to ensure fi xture is operating under correct mode, IE

sound active/auto/DMX/Etc., if applicable. Contact service

for more information.

Chase Speed

Too Fast/Slow

Check to ensure proper setup of speed adjustment.

No Power

Check fuse, AC cord and circuit for malfunction.

Blown Fuse

Check AC cord and circuit for damage, verify that moving

parts are not restricted and that unit’s ventilation is not

obstructed

Slow Movement Verify that 220V/110V switch is in the correct position, if

applicable. Also check that speed channels are set appropri-

ately.

No Response to

Audio

Verify that the fi xture is in “Sound Active” mode.

Adjust Audio Sensitivity, If Applicable.

Fixture Not

Responding /

Responding Er-

raticly

Make sure all connectors are seated properly and securely.

Use Only DMX Cables.

Install a Terminator.

Check all cables for defects.

Reset fi xture(s).

Intermittant

Lamp

Check lamp for properly installation.

Relamp, lamp may have reached end of life.

Remote Doesn’t

Work

Verify remote control cable is installed properly and securely.

Verify remote is correct type (CA-9 or other as applicable.)

Fixture Moving

On Its Own

Verify proper mode of operation. Is the fi xture in “Auto”

mode?

If your problem isn’t listed, or if problems persist,

please contact support: [email protected].