beautypg.com

Bendix Commercial Vehicle Systems BA-922 COMP User Manual

Page 8

background image

Bendix

®

BA-922

®

Compressor Installation and Application Review

Page 8 of 14

BW2514 ©2006 Bendix Commercial Vehicle Systems LLC • All Rights Reserved • 3/22/06 • rev: 1.


Discharge

line

First component after compressor (filters, separators, traps, dryers)


What:

_________________________________________

Line ID size to: ____________________________________

Distance

to:

____________________________________


Second

component

after

compressor

(filters, separators, traps, dryers)

What:

_________________________________________

Line ID size to: ____________________________________

Distance

to:

____________________________________


Third component after compressor (filters, separators, traps, dryers)

What:

_________________________________________

Line ID size to: ____________________________________

Distance

to:

____________________________________

Is the discharge piping routed in a downhill manner to the air dryer?

YES

NO



Measured compressor discharge pressure

(measured at the compressor) ______________________


Recommended

Test

Procedure:

Install a pressure gauge at the discharge fitting of the compressor and record the
discharge pressure at the time of governor cut-out.
Note, any devices in the discharge line between the compressor and air dryer should
represent their maximum possible restriction when the discharge pressure of the
compressor is being measured.

Was measured discharge pressure greater than 150 psi? YES

NO