Maintenance – Bowflex TreadClimber 5000 User Manual
Page 33
Owner’s Manual
29
Maintenance
Main Power Switch “On”
TC5000 Power & Slower Buttons
/
POWER MODULE
+
-
TO START:
1. Press
POWER
2.
10019 MM2217
TC3000 Power & Slower Buttons
Calibration (TC3000 & TC5000)
Do not use the machine for exercise purposes without
completing Calibration (TC3000/5000).
It is important to calibrate (TC3000/5000) after a power
outage or after any electrical repair or replacement.
Failure to follow this procedure prior to use could result
in machine failure and could cause injury.
Do not stand on the Walking Belts during calibration.
During the entire process, stand on the side foot support
platforms or beside the machine.
Note: During calibration, observe the walking belt alignment.
Belts do not need to be perfectly centered, but if they
are far enough from center to cause a scraping sound,
follow the Belt Alignment instructions in the Owner’s
Manual.
1. Plug the power cord into the the wall outlet. Turn on
the red Power Switch at the rear of the machine.
2. Stand on the side foot support platforms or beside the
machine. DO NOT STAND ON THE WALKING BELTS.
3. Press and hold down the POWER and SLOWER
buttons.
4. Insert the Safety Key.
Note: If the Safety Key is not fully inserted into the safety
keyhole, the TreadClimber
®
machine will not
operate.
5. Release the POWER and SLOWER buttons. The TIME
display will show “CAL”, PrSS”,”Strt”.
6. Press the START/STOP button to start calibration.
Note: The belts will start and stop and the displays will
show various numbers that relate to the calibration
process. Do NOT interrupt calibration. If calibration
is interrupted, turn off the power switch at the rear of
machine and go back to Calibration Step 1.
7. Calibration will take about 30 seconds. When calibration
has completed, belts will stop and calibration results will
show in the TIME display.
8. If the display shows “CAL PASS” or “CAL DONE”,
remove and re-insert the safety key. Machine is ready to
use. Review Owner’s Manual for operating instructions.
If the display shows “CAL FAIL” or any other message, do
not use machine. Contact Customer Service for assistance
immediately at 1-800-605-3369.
Note: During calibration the 30 meter LED on the
TC5000 signifies the belt speed sensor, 305
meters LED is the step sensor. Some models
of the TC 3000 will show the step sensor in the
DISTANCE window as a heart and the speed
sensor in the SPEED window as a heart.