Bendix Commercial Vehicle Systems TU-FLO 501 AIR COMPRESSOR 9/04 User Manual
Page 12

12
6.
Never exceed manufacturer’s recommended
pressures.
7.
Never connect or disconnect a hose or line
containing pressure; it may whip. Never remove a
component or plug unless you are certain all
system pressure has been depleted.
8.
Use only genuine Bendix
®
replacement parts,
components and kits. Replacement hardware,
tubing, hose, fittings, etc. must be of equivalent
size, type and strength as original equipment and
be designed specifically for such applications and
systems.
9.
Components with stripped threads or damaged
parts should be replaced rather than repaired. Do
not attempt repairs requiring machining or welding
unless specifically stated and approved by the
vehicle and component manufacturer.
10. Prior to returning the vehicle to service, make
certain all components and systems are restored to
their proper operating condition.
11. For vehicles with Antilock Traction Control (ATC),
the ATC function must be disabled (ATC indicator
lamp should be ON) prior to performing any vehicle
maintenance where one or more wheels on a
drive axle are lifted off the ground and moving.
TABULATED DATA
Number of cylinders
2
Bore size
2.625 in.
Stroke
1.50 in.
Piston displacement at 1250 RPM
12 cu. ft.
Piston displacement per revolution
16.5 cu. in.
Maximum recommended RPM
(naturally aspirated)
3000
Minimum coolant flow at maximum RPM
2.5 gal./min.
Horsepower required at 3000 RPM
against 100 PSI head pressure
4.9 H.P.
Recommended minimum discharge
5/8 in. OD
line size
Copper Tube
Recommended minimum oil return
line size
5/8 in. OD Tubing
Recommended minimum oil supply
line size
1/4 in. OD Tubing
Recommended minimum unloader
line size
1/4 in. OD Tubing
Recommended minimum inlet cavity line
size (when compressor is
connected to engine air cleaner)
5/8 in. ID
minimum
Recommended minimum coolant line
size
1/2 in. OD Tubing
Recommended maximum inlet air
temperature
250°F
Recommended maximum discharge
air temperature
400°F
Minimum pressure required to unload
60 PSI