6.0 System Messages and Run Messages
6.1 Power-Up Fault Messages
Messages that are displayed during power on self-test. If PLC System Errors are shown in the display, call service.
ENGLISH
GERMAN
CODES
TYPE
DESCRIPTION
88888
88888
88888
Information The controller is performing its lamp test.
MEM TEST
MEM TEST MEM TEST Information The controller is performing its RAM test.
All Blank
All Blank
All Blank
PLC System The display board is not functioning.
Error
Cycle Power. If error persists, call service.
ID Fail
ID Fail
ID Fail
PLC System System cannot recognize the controller board.
Error
Action: Cycle Power, if error persists call service.
Error 1
Error 1
Error 1
PLC System The RAM test has found a bad memory location.
Error
Action: Cycle Power, if error persists call service.
Error 2
Error 2
Error 2
PLC System The Pile Safety Relay is stuck on or there is no power supply to the
Error
pile circuits. Action: Check the condition of Relay 1 (K1), Fuses
F1 and F2, and X18. Cycle Power. If error persists, call service.
Error 3
Error 3
Error 3
PLC System There is power in the Pile Drive when it is off. Action: Check the
Error
condition of Relay 1 (K1), Fuses F1 and F2, and X18. Cycle
Power. If error persists, call service.
Error 4
Error 4
Error 4
PLC System The 24VAC inputs have current before the Watchdog relay has
Error
been activated. Action: Check for stuck push buttons, faulty
sensors, or loose connectors. Cycle Power. If error persists, call
service.
Error 5
Error 5
Error 5
PLC System The membrane switch panel has a key pressed during the power
Error
on self-test. Action: Cycle Power, if error persists call service.
Error 6
Error 6
Error 6
PLC System The Watchdog sense circuit indicates Watchdog-timer operational
Error
before it has been started. Action: Cycle Power, if error persists
call service.
Table 16. Power Up Fault Messages