ATIK Cameras OAG User Manual
Page 2

Using your OAG
The OAG is very easy to use and adjust. Looking at all components individually:
5
6
7
The main body (6) is where all the action happens. The pickup prism bends the light path through 90º, to the guide camera. You can
attach the OAG to the telescope using the 2” adapter (5). Also, a kit of extension rings (7) is supplied, so that different guide cameras
can be used with different main cameras, in several different combinations. The choice of extension to use is governed by the main
camera, guide camera, pickup prism position and even the telescope. You will need to do some experimentation to find the right
combination of rings. Both the OAG and the rings have T-threads, so they will fit any camera with T-threads.
To adjust the pickup prism, you need to slightly undo the locking screw (the access hole is just below the locking screw), making sure
that you undo it only “slightly”. There’s a captive recess that will prevent the prism support to falling, but this will not work if the screw
in undone too much, causing the support to fall out of place.
Use your finger to move the prism support to the desired position, and then tighten the locking screw. Again, the correct position will
depend on the main camera and telescope used. As an example, an Atik 11000 will probably need the prism all the way in, to avoid
shadows, and if an SCT is used you’ll probably want to lower the prism as much as possible, to get better star shapes.
Focusing your OAG
One of the great features of the Atik OAG is the extremely smooth focus mechanism:
Simply adjust the focusing ring counter-clockwise, and the camera support will smoothly and precisely go up: turn clockwise, and it
will go down. It’s as easy as that! When focused, just tighten the locking ring slightly (don’t over tighten!), so that the assembly keeps
rock solid! There’s a total travel of about 5mm which, in addition to the supplied rings, will be enough to make it easy to focus your
guide camera.