WIRING SYSTEM CHANGES

Beckett burners have taken advantage of the changes in the R7184 controls to improve the wiring
system. Component and power cord wires, now color-coded to match the terminal colors on the
control, are terminated with 0.25-inch flag terminals (QCs) to fit the spade connectors (QCs) on the
control. During the time required to convert all components and controls to the new wiring system,
some adaptations may be required when replacing individual components on the burner.

CHANGING COMPONENTS — When changing components, the type of connection that you need
to make depends on the way the components (motor, valve, igniter), power cord and control are
terminated. Where all the leads / connections are the same, no modifications are required. Where
the two ends of a connection are dissimilar, see the options in the following table:

Reduced number of leads in wiring box.

Fig. 1 – Cutting lead from component to be

replaced to use as jumper

Fig. 2 – Using jumper to connect to new

component with stripped leads

Beckett Service Kits for termination conversion:

51947 – Full service kit including a full complement of (6) QC pigtails (BLK, W, O, BLU, V, R), (6) wire

nuts and (9) 0.25-inch flag terminals, and this instruction sheet.

51948 – Termination kit including (9) 0.25-inch flag terminals, (6) wire nuts, and instruction sheet.

If you have any questions regarding controls or the Beckett R7184 primary control by Honeywell,
please contact R.W. Beckett at 1-800-645-2876 or visit our web site at www.beckettcorp.com.

If your components are

terminated like this:

You should use the following:

Components

Stripped end

Flag terminal

Flag Terminal

Stripped end

Control

Wire leads

Spade

Wire leads

Spade

Connection options

• Wire nuts

• QC (Quick Connect)

• Cut flag terminal and strip

end – Wire nut

• Add flag terminal to component

lead – QC

• Cut existing component lead 6 -7

in. from flag terminal and strip

end – Wire nut (Fig. 1 & 2)